Series ID Camera Installation
Use a thread locking compound such as Loctite 242 or equivalent with all metal to metal threaded
connections.
Once the holes are drilled in the mounting surface, install three (3) to five (5) 1/4-20 threaded
fasteners into the base of the camera with thread-locking compound.
Secure the camera to the mount with three (3) to five (5) 1/4-20 threaded fasteners as shown below.
1.3.9
Removing the Back Cover
Use a 3 mm hex key to loosen the four captive screws,
exposing the connections at the back of the camera
enclosure. There is a grounding wire connected
between the case and the back cover as shown. If the
grounding wire is temporarily disconnected during the
installation, it must be reconnected to ensure proper
grounding of the camera.
1.3.10
Cable Gland Sealing
Proper installation of cable sealing glands and use of
appropriate elastomer inserts is critical to long term
reliability. Cables enter the camera mount enclosure
through liquid-tight compression glands. Leave the
gland nuts loosened until all cable installation has been
completed. Inspect and install gland fittings in the back cover with leak sealant and tighten to ensure
water tight fittings. Teflon tape or pipe sealant (i.e. DuPont RectorSeal T™) are suitable sealants.
Figure 1-2: F
-
Series ID Camera Mounting Holes