21
Onboard Weighing |
FT-30M
| www.flintec.com
Empty
Weighbridge:
5,840kg
14� Channel 2 Calibration - Trailer Tare
Begin Channel 2 calibration.
Press :
11� Tractor Tare Weight
Swipe up or down to input the tractor Tare weight. (10,580kg)
Press :
12� Tractor Tare mV/V
Confirm the tractor Tare mV/V.
Press :
13� Channel 1 - Tractor Tare Calibration Done
Return to calibrate Channel 2 Tare.
Press :
10� Tractor Tare
Weigh and record unladen
tractor
. (Tare weight)
Press :
to enter the Tare weight.
15� Trailer Tare
Weigh and record unladen
trailer
. (Tare weight)
Press :
to enter the Tare weight.
16� Trailer Tare Weight
Swipe up or down to input the trailer Tare weight. (5,840kg)
Press :
to enter the Tare weight.
17� Trailer Tare mV/V
Confirm the trailer Tare mV/V.
Press :
Empty
Weighbridge:
10,580kg
Calibration - Dual Channel
9� Channel 1 Calibration - Tractor Tare
Begin Channel 1 calibration.
Press :
*mV/V is the signal level from the load cells and must be stable.
Flickering indicates a problem with a load cell, connection or the load
is moving.
*mV/V is the signal level from the load cells and must be stable.
Flickering indicates a problem with a load cell, connection or the load
is moving.
v1_000023_FT-30M 21/06/2016