background image

FAA-28, Technical Manual, Rev.1.1.0 

February 2022 

 

 

Page 3 of 21 

2.  Front View, Features and Specifications 

High speed analog load cell transmitter FT-28 has very high accuracy and long term 
stability with its high tech design. Its high performance electronic calibration via 
RS232C serial port without any test weight and fast calibration without measuring 
output signal reduces commissioning and service times. 

 

This high tech instrument gives the system designers a lot of advantages to increase 
the system reliability and to reduce the installation and service times. Besides the 
traditional analog output adjustment with any test weight, the electronic calibration 
eCal and fast calibration with 20% max. test load reduces the calibration time.  
All analog outputs of the instruments are matched in the production to perform 
calibration at PLC and for changing the instrument without recalibration in service. 

 

There are 8 positioned rotary switches and annunciator LEDs in front of the 
instrument. The front view and pin descriptions of FAA-28 is shown below. 

 

 

Pin Name 

Definition 

  

LOAD CELL CONNECTION 

+ Ex 

+ Excitation 

- Ex 

- Excitation 

+Se 

+Sense 

-Se 

-Sense 

+ Si 

+ Signal 

- Si 

- Signal 

 

Shield and Protective ground  

  

ANALOGUE OUTPUT 

Current output 

Voltage output 

GND 

  

SERIAL CONNECTION 

TX 

TxD  ( RS232C ) 

RX 

RxD  ( RS232C ) 

Ground ( RS232C ) 

Zeroing input (0V) 

Zeroing input (+24V) 

  

SETPOINT CONNECTION 

Q1 

Digital Output 1 

Q2 

Digital Output 2 

Com 

Digital Outputs Common  

POWER SUPPLY 

24V

 

+24VDC 

0V

 

    0VDC 

 

 

 

 

FAA-28 

Summary of Contents for FAA-28

Page 1: ...FAA 28 Analog Amplifier Technical Manual Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www flintec com...

Page 2: ...sioning 9 4 Adjustments 10 4 1 Adjustment with Rotary Switches 10 4 2 Fast Adjustment to Nominal Output Range 12 4 3 eCal Electronic Adjustment Via xFace Software 12 4 4 Adjustment eCal With PLC 13 4...

Page 3: ...this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical photocopying recording or otherwise without the prior written permission of Flint...

Page 4: ...t the electronic calibration eCal and fast calibration with 20 max test load reduces the calibration time All analog outputs of the instruments are matched in the production to perform calibration at...

Page 5: ...to chapter 9 Features Minimized zero and span drifts due to its microcontroller technology and high accuracy very low temperature drift 24 bits ADC and 16 bits DAC converters Long time stability and l...

Page 6: ...PC Preadjusted instrument for calibration at PLC Digital Filter Programmable 9 step adjustable digital adaptive filter Analogue outputs Current output for 0 20 mA and 4 20 mA or voltage output for 0 5...

Page 7: ...nst radio frequency interference and the cabinet shall be connected to ground against the electromagnetic disturbances Load cell cable and analog output cable trays must be separated from others if po...

Page 8: ...rgizing to avoid damages of the instrument and load cells In 4 wire installations the sense and excitation pins with the same polarity should be short circuited at the connector side If you have junct...

Page 9: ...one of the analog output types can be used at the same time and has to be selected in the setup type Install the analog output measuring instrument for adjustment e g multimeter Pin Name Definition I...

Page 10: ...osition Connect or disconnect TxD and RxD pins according the table above to set the output range Turn the adjustment switch to the position After 2 seconds turn in back to the 0 position if the instru...

Page 11: ...flashes to indicate the instrument is not in operation mode Zero Adjustment Connect the measurement instrument Multimeter is recommended to the analog output Unload the scale the scale must be empty...

Page 12: ...2 5VDC Turn the adjustment switch to the G position from the analog output type position you set before Increase or decrease the analog output by adjustment rotary switch to the calculated output val...

Page 13: ...n and turn it back to 0 position 2 seconds later Turn the programming switch to analog output type position for operation For example for 4 20mA range and for 100kg capacity scale load the scale 20kg...

Page 14: ...RS232C serial interface by commands or by xFace software If you want to use your own software to calibrate the FAA 28 from your PLC or PC you may use the commands below The yellow colored bytes are th...

Page 15: ...01100009000204000000FAE6 Scale capacity is 250kg Response 011000090002E4 ACK Step 6 SAVE with estimated dead load value Command 011000000001020007E5 Save the eCal values Response 011000000001EE ACK Or...

Page 16: ...e_Add Function Last_data STX and CSUM are neglected while calculating CSUM Example For Medium 1 filter 011000220001020001XX CSUM 0 01 10 00 22 00 01 02 00 01 0 37 C9 Command is 011000220001020001C9 Ca...

Page 17: ...n the programming switch to S1 or S2 position from operation position from V or I position Turn the Adj switch to positions position and turn it back to 0 position 2 seconds later Turn the programming...

Page 18: ...ted Off 0 10VDC Open circuited Flash 0 5VDC Short circuited Blinking The status of the LEDs in the operation type is given in the table below Refer to chapter 9 in case of the Err LED turns on The ana...

Page 19: ...ntains the xFace software v2 03 or higher into the CD ROM drive Double click Setup exe to start the installation The setup Wizard will be displayed Follow the menus in the setup wizard step by step Af...

Page 20: ...oints in section Setup 9 In section Status instrument information are available 10 Power off the instrument before disconnecting from PC Bring the programming switch to the analog output type position...

Page 21: ...not let unauthorized people interfere with the instrument FRONT PANEL LEDS DEFINITION Run V I Err Off Off Off No power Board failure On On Off Operation in 4 20mA output type On Off Off Operation in...

Page 22: ...FAA 28 Technical Manual Rev 1 1 0 February 2022 Page 21 of 21 Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www flintec com...

Reviews: