B.2
SETUP TABLE
Page 6
Manual DAS 72.1
Description
LED Display
Pre Setup
Example: 3000 kg scale
with 0.5 kg step
Menu Point
Value
Value
Result
Function Zero key (on/off))
Zero Calibration / Weight
Zero Calibration / mV/V
< 1.1 >
< 1.2 >
< 1.3 >
0-oFF
0.000
0.000
0-oFF
0.000
0.400
Set zero not
possible
kg
mV/V
Span / Weight or mV/V
Span / Weight
Span / mV/V
Displays Actual mV/V Signal
< 2.1 >
< 2.2 >
< 2.3 >
< 2.4 >
20000
0.000
2.000
--
a)3000.0 or
b)750.0
0.9
2.000
--
Cal. with mV/V
Cal. with 750 kg
mV/V
mV/V
--
Maximum Display Value
Maximum Display Value
Display Step Size
Decimal Point Position
Display Status I/O
< 3.1.o >
< 3.1.u >
< 3.2 >
< 3.3 >
< 3.4 >
99999
-9999
1
0
1
3100.0
-200.0
5
0.0
1
kg
kg
0,5 kg
0000.0
Status for 1 s
Cut Off Filter Frequency
Filter Type
Update Rate per second (filtered)
No Motion Range
< 4.1 >
< 4.2 >
< 4.3 >
< 4.4 >
33.3
FIR
3
1
3.0
FIR
3
1
Hz
for quick signal
changes
measurements/s
Set Analogue Output @ 4 mA
Set Analogue Output @ 20 mA
Base of Analogue Output
Simulate Analogue Output Signal
< 5.1 >
< 5.2 >
< 5.3 >
< 5.4 >
00000
20000
gross
--
0.0
3000.0
gross
--
kg
kg
gross
--
Input 1 for External Key Control
Input 2 for External Key Control
Input 3 for External Key Control
Read Iinput Status
Base of Digital Inputs
Test Logic Inputs
< 6.1.1 >
< 6.2.1 >
< 6.3.1 >
< 6.2 >
< 6.3 >
< 6.4 >
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Output Setpoint 1
Output Setpoint 2
Output Setpoint 3
Hysteresis & Logic Setpoint 1
Hysteresis & Logic Setpoint 2
Hysteresis & Logic Setpoint 2
Base Setpoint 1
Base Setpoint 2
Base Setpoint 3
Function Test Output 1
Function Test Output 2
Function Test Output 3
< 7.1.1 >
< 7.2.1 >
< 7.3.1 >
< 7.1.2 >
< 7.2.2 >
< 7.3.2 >
< 7.1.3 >
< 7.2.3 >
< 7.3.3 >
< 7.1.4 >
< 7.2.4 >
< 7.3.4 >
99999
00000
oFF
--
--
--
--
--
--
--
--
--
0000.0
1000.0
3000.0
0000.0
0000.0
0000.0
net
net
net
--
--
--
kg
kg
kg
kg
kg
kg
net
net
net
--
--
--
Baudrate RS-422/485 Port
Port Mode (422 or 485)
Device Address Com Port
Auto Transmit Data
< 8.1 >
< 8.2 >
< 8.3 >
< 8.4 >
9600
422
0
oFF
9600
422
0
nEt
Baud
422-Port
Device No.
auto transmit
net weight