C.3
COMMANDS SUMMARY
Manual DAS 72.1
Page 27
Command
Short
D
escription
Usage
P
arameter
Values
Typical
A
nswer
AA
Get/set
analog
action
A
nalog
action
0
through
8
A
+00000/OK/ERR
AD
Network
address
R
ead/modify
N
etwork
address
0
through
255
A:014/OK/ERR
AG
Absolute
gain
calibrate
(TAC
protected)
C
ailbrate
gain
using
absolute
sensitivity
in
mV/V
(without
dp)
+/-32000;
0
through
99999
G+2.0000/OK/ERR
AH
Get/set
analog
h
igh
A
nalog
calibration
point
2
0
m
A
(high)
-99999
through
9999
H+10000/OK/ERR
AIn
Action
input
n
Function
of
logic
input
1,
2
or
3
0
through
14
In:+00006
AL
Get/set
analog
low
Analog
calibration
point
4
mA
(low)
-99999
through
99999
L+00000/OK/ERR
An
Get/set
setpoint
n
action
S
etpoint
action
1
,
2
or
3
0
through
8
A
n:+00000/OK/ERR
AS
Save
analog
output
parameters
Save
AL,
A
H,
AA
to
EEPROM
n
one
O
K/ERR
AZ
Absolute
zero
calibrate
(TAC
protected)
C
albrate
zero
u
sing
absolute
zero
in
mV/V
(without
decimal
p
oint)
-32000
through
32000
Z+0.000/OK/ERR
BR
Baudrate
R
ead/modify
b
audrate
setting
9600
through
115200
B
9600
CE
Calibrate
enable
Open
legal
p
arameters
(CE
'TAC')
0
through
65535
E+00001/OK/ERR
CG
Calibrate
gain
(TAC
protected)
C
alibrate
gain
at
some
load
>>
zero
0
through
99999
G+20000/OK/ERR
CI
Calibrate
min
(TAC
p
rotected)
R
ead/modify
m
in
0
through
-99999
I+09000/OK/ERR
CL
Close
all
connections
Close
all
devices
(OP
XXX
implies
C
L)
none
none
CM
Calibrate
max
(TAC
p
rotected)
R
ead/modify
m
ax
0
through
99999
M+30000/OK/ERR
CS
Calibrate
save
(TAC
protected)
S
ave
C
M,
CZ
,
A
Z,
CG,
AG,
D
S,
DP,
Z
T
to
EEPROM
n
one
O
K/ER
CZ
Calibrate
zero
(TAC
protected)
C
alibrate
zero
-
n
o
load
on
platform
none
OK/ER
DP
Decimal
p
oint
(TAC
protected)
R
ead/modify
d
ecimal
p
oint
position
0
through
5
P
+00005/OK/ERR
DS
Display
step
size
(TAC
p
rotected)
R
ead/modify
the
display
step
size
1
,
2
.5,
10,
20,
50,
100,
200,
500
S+00001/OK/ERR
DX
Duplex
Select
half
(0)
or
full
(1)
duplex
0
oder
1
X+000/OK/ERR
FD
Factory
d
efault
(TAC
protected)
Load
factory
d
efaults
into
EEPROM
n
one
O
K/ER
FL
Filter
setting
Read/modify
filter
setting
0
through
8
F+00008/OK/ERR
FM
Filter
mode
Read/modify
filter
mode
setting
0
oder
1
M+00001/OK/ERR
GA
Get
A
verage
weight
Returns
the
current
average
value
none
A+00000
GG
Get
G
ross
value
R
eturns
the
g
ross
value
n
one
G
+01100
GH
Get
H
old
value
Returns
the
hold
value
n
one
H
+01000/OK/ERR
GM
Get
P
eak
value
(maximum)
Returns
the
peak
value
n
one
M
+00100
GN
Get
N
et
value
R
eturns
the
n
et
value
n
one
N
+00000
GO
Get
P
eak
to
Peak
value
R
eturns
the
P
eak
to
Peak
value
n
one
O
+01000/OK/ERR
GS
Get
sample
R
eturns
the
A
/D
value
n
one
S
+000000
GT
Get
T
are
value
Returns
the
tare
value
n
one
T
+00000
GV
Get
Valley
value
(minimum)
R
eturns
the
valley
value
none
V+01000/OK/ERR
GW
Get
long
W
eight
information
G
et
long
weight
information
n
one
W
+00100+01100010F
Hn
Get/set
setpoint
n
hysteresis
Setpoint
hysteresis
1,
2
or
3
-99999
through
99999
Hn:+00000/OK/ERR