C.4.13 Save parameters Commands – CS, WP, SS, AS, TH
The setup and calibration parameters can be divided into 4 groups:
•
Calibration parameter: CZ, CG, CM, CI, DS, DP, ZT, are saved by the CS command.
•
Setup parameters (other than setpoint): FL, FM, NR, NT, BR, AD, DX etc are saved by the WP command.
•
Setpoint parameters: Sn, Hn, Pn, An are saved by the SS command.
•
Analogue output parameters: AA, AH, AL are saved by the AS command.
•
Store Actual Weight saved by “TH“
CS
Save Calibration Parameters
Calibration parameters can only be saved if the TAC code is known and precedes the CS command. See the
CE and CS commands on page 33.
WP
Save the setup parameters
With this command the settings of the “Filter” (FL, FM) ,the “No-Motion” (NR, NT) and the communication
(AD, BR, DX) will be saved in the EEPROM.
Master ( PC / PLC ) sends
DAS 72.1 responds
Result
WP
¿
OK
Parameter saved
WP
¿
ERR
Error
SS
Save the “setpoint” set-up parameters
With this command the settings of the setpoints (Sn), the “setpoint hysteresis” (Hn), the “switch logic” (Pn)
and the “setpoint action” (An) will be saved in EEPROM.
Master ( PC / PLC ) sends
DAS 72.1 responds
Result
SS
¿
OK
Parameter saved
SS
¿
ERR
Error
AS
Save the analogue output parameters
With this command the settings of the analogue output setup (AA, AH and AL) will be saved in EEPROM.
Master ( PC / PLC ) sends
DAS 72.1 antwortet
Result
AS
¿
OK
Parameter saved
AS
¿
ERR
Error
TH
Save the actual weight
With this command the settings of the actual weight will be saved in EEPROM.
Master ( PC / PLC ) sends
DAS 72.1 antwortet
Result
TH
¿
OK
Parameter saved
TH
¿
ERR
Error
Manual DAS 72.1