CCWR - User Manual
Doc No.
0096489
Page
15
of
29
V1.2 Issued 17 Aug 2020
5.
Operation
1.
Disconnect or remove the power to the base unit.
2.
Ensure the base antenna is connected with an RF filter. The RF filter must always be
mounted on the base
3.
The remote antenna is installed by the manufacturer; to preserve safety certifications, it is
not intended to be removed.
4.
Ensure the manufacturer supplied battery is connected to the remote unit.
5.
The remote unit indicator LED, if viewable, will flash about twice per second.
6.
Connect or apply power to the base unit.
7.
The base and remote will connect on the last-used radio channel in about a second.
8.
If the base is set to use an alternative channel, it will automatically switch the remote to
the new channel. This will take a few seconds to reconfigure.
9.
Normal operation begins.
10.
A reconstructed version of the mV/V nominal load cell output will appear at the base
output (for mA variant this is a 4-20mA current loop).
11.
If radio interference occurs, an alternative channel may be selected.