6.
Technical Specification
CCWR Retrofit Wireless System Technical Specification
Typical System Specifications with Flintec CC1 &
CC3
Variants/Capacities
lb
30k & 50k
Rated Load Output (RO)
mV/V
2.00 ± 0.5%
Rated Position Output
% FS (Stroke)
± 2
Non-Repeatability
% RO
± 0.1
Static Error Band
% FS Max
± 0.5
Compensated Temperature Range
°F (°C)
-14° to 150° (-25° to 65°)
Safe Operating Temperature Range
°F (°C)
-70° to 175° (-55° to 80°)
Temperature Effect on Zero
% RO/°F Max
± 0.0075
Temperature Effect on Output
%RO/°F Max
± 0.005
Zero Balance
% RO Max
± 1
Weight, (Appr. Remote Unit + LC e.g. CC1)
lb Nom.
4.5
Fatigue Rating (compression)
Cycles Min@Capacity
50,000,000
Shock Rating
g
Up to 500g
Vibration Rating
MIL-STD-810G
514.6; 516.6
Load-Cell Requirements
Rated Load Output (Nominal RO)
mV/V
2
Excitation Voltage
V
+5V
DC
to +10V
DC
Insulation Resistance (100V
DC
)
MΩ
≥ 500
Bridge Resistance
Ω
≥ 350
Protection According to EN 60529
IP67