44
GATEWAY SPECIFICATION - WebdynPulse
WebdynPulse – Gateway specification - Version 2.0
10.4 Installation button
The
INSTALL
button, fitted on the front panel of the unit, enables forced connection or restart of the
gateway as explained in the table:
ACTION
CONSEQUENCE
Press the
INSTALL
button for about 1 second
until the
SERVICE
LED flashes
Besides the actions defined in §
10.3.3
Connection
, the gateway uploads the inverter
parameter file.
Press the
INSTALL
button for about 10 seconds
until all the LEDs on the gateway go out
The gateway restarts
(the LEDs light up again about 1 minute after the
restart begins)
10.5 Diagnostic SMSs
Besides the configuration SMSs described in previous chapters, some SMSs can enable initial
diagnosis of a problem with the WebdynPulse:
SMS
Description
connect
Requests a connection to the remote server
version (*)
Requests the current software version of the unit
reboot
Initiates a restart of the product
status (*)
Requests information on the current configuration of the
unit:
•
Unit type: WebdynPulse
•
Unit identifier (prefixID)
•
Software version
•
Connection mode (GPRS or LAN)
•
Information on the APN configured
•
SIM card identifier
•
GSM signal strength (RSSI)
•
Information on the Ethernet interface (IP,
router, DNS, etc.)
•
Information on the remote FTP server
diag (*)
Requests diagnostics on the unit interfaces:
•
DI: status of the bang-bang inputs configured
•
DX: status of the index inputs configured
factory
Initiates a factory reset of the unit
(*) Operational only if the option to send SMSs is enabled.
10.6 Debug traces
Occasionally, it is necessary to enable debug traces, so as to be able to diagnose a problem.