5.1.4
Alarms
The hub can generate system alarms.
There are 3 types of system alarm:
•
Modem IP
: alarm generated if the IP address obtained during a modem connection
changes
•
MSISDN
: alarm generated if the SIM card inserted in the hub is replaced
•
SW Version
: alarm generated if the firmware or core versions change (following an
update)
Each alarm source can be enabled separately and immediately transferred to the remote
server (
On
) or transferred at the next connection (
Delayed
).
The hub malfunction alarms (“
Default
”) are sent to the remote server immediately by default.
They can however be disabled (“
Ignored
”) or delayed (“
Delayed
”) and sent at the next
connection. To do that, the codes must be entered in the fields corresponding to the required
behaviour.
Below are the available codes and faults:
Code
Description
D_MODEM
Modem fault
D_MODEM_SIM_MISS
SIM card missing
D_MODEM_SIM_CODE_FAIL
SIM code error
D_MODEM_PUK
SIM card locked
D_MODEM_REG_DENIED
Network registration declined
The fault codes ignored by the hub can be listed in the
Ignored
box. If several fault codes are
entered, they must be separated by a comma “,”.