![Flexitron Webdyn WebdynEasy LoRaWAN User Manual Download Page 21](http://html1.mh-extra.com/html/flexitron/webdyn-webdyneasy-lorawan/webdyn-webdyneasy-lorawan_user-manual_2304913021.webp)
21
USER MANUAL - WebdynEasy LoRaWAN
Version 0.10
the product. To do this, unscrew the cap on the box and fit a M16*1.5 cable gland (not
included).
To optimise the radio range, it is important to install the radio antenna as high as possible
and to place it carefully, avoiding obstacles as far as possible. As a priority, move it away
from any metal (cupboard, beams...) or concrete (reinforced concrete, walls...) obstacles as
they greatly attenuate radio waves.
End users must make sure their installation using
remote antennas
meets
applicable EMC standards.
4.2.5
Connection
4.2.5.1
Power supply
The WebdynEasy hub must have a 12V or 24V DC power supply. Power is supplied from
terminal block J11 on the bottom left side of the board.
End users must use a CE certified power supply of less than 15 watts. The distance
between the power supply and the product must not exceed
3 metres
. End users
must make sure their installation meets applicable EMC standards.
Internal Antenna
External antenna
Cap
External antenna
cable gland
Internal antenna
SMA connector