Modem
Lights when the Modem sets up an IP connection
Lights for 1 second on receipt of a text message
Following a long press on the Request button, it indicates the received
signal level (RSSI) using a number of flashes (0 to 5 times)
0 – signal power ≤ -112 dBm
1 – signal power between -111 dBm and -96 dBm
2 – signal power between -96 dBm and -81 dBm
3 – signal power between -81 dBm and -66 dBm
4 – signal power between -66 dBm and -51 dBm
5 - signal power > -51 dBm
Buttons:
Button
Description
Request
Short press (less than 2 seconds) => Connection request
Long press (more than 2 seconds) => Displays the Modem signal reception
level (see Modem LED)
3 successive long presses in less than 15 seconds => Return to factory
settings
Reset
Hub reboot (Hard Reset)
Never press the RESET button 7 times in less than 30 seconds. This would switch
the hub to a special mode that prevents it from starting. To exit the mode, a new
hub RESET is required.
End users must make sure their installation using
remote antennas
meets
applicable EMC standards.
3.2.2
Technical Specifications
3.2.2.1
General specifications