![Flexim FLUXUS WD100 User Manual Download Page 50](http://html1.mh-extra.com/html/flexim/fluxus-wd100/fluxus-wd100_user-manual_2304737050.webp)
10 Displaying the Measured Values
50
UMFLUXUS_F5WDV1-1EN, 2016-04-08
Press key
during the measurement to change the display in the upper line, press key
to change the display in
the lower line.
10.3
Status Line
Important data on the ongoing measurement are displayed in the status line. The quality and precision of the ongoing
measurement can be estimated.
The character
*
indicates that the displayed value (here: flow velocity) is not the selected
physical quantity.
Press key
during the measurement to scroll through the upper line to the status line.
value
explanation
S
signal amplitude
0
…
9
< 5 %
…
90 %
Q
signal quality
0
…
9
< 5 %
…
90 %
c
sound speed
comparison of the measured and the expected sound speed of the fluid. The expected sound speed
is calculated on the basis of the fluid parameters (fluid selected in the program branch
Parameter
,
temperature dependence).
√
ok, is equal to the expected value
↑
> 20 % of the expected value
↓
< 20 % of the expected value
?
unknown, cannot be measured
R
flow profile
information about the flow profile based on the Reynolds number
T
fully turbulent flow profile
L
fully laminar flow profile
↕
the flow is in the transition range between laminar and turbulent flow
?
unknown, cannot be calculated
F
flow velocity
comparison of the measured flow velocity with the flow limits of the system
√
ok, the flow velocity is not in the critical range
↑
the flow velocity is higher than the current limit
↓
the flow velocity is lower than the current cut-off flow (even if it is not set to zero)
0
the flow velocity is in the offset range of the measuring method
?
unknown, cannot be measured
Flow Velocity
*
2.47
m/s
S3 Q9 c
RT F
Summary of Contents for FLUXUS WD100
Page 1: ...User Manual UMFLUXUS_F5WDV1 1EN Ultrasonic Flowmeter for Water FLUXUS WD100 FLUXUS WD200...
Page 4: ...FLUXUS WD100 WD200 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 8: ...FLUXUS WD100 WD200 Table of Contents 8 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 104: ...FLUXUS WD100 WD200 D Declarations of Conformity 104 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 105: ......
Page 106: ......