6 Installation of the Transmitter
30
UMFLUXUS_F5WDV1-1EN, 2016-04-08
• Insert the extension cable into the junction box.
• Prepare the extension cable.
• Cut the outer shield and brush it back.
• Pull the extension cable back until the brushed back external shield is below the shield terminal (see Fig. 6.9). The exten-
sion cable must remain completely insulated up to the shield terminal.
• Screw the gasket ring side of the basic part into the junction box.
• Fix the cable gland by screwing the cap nut onto the basic part.
• Fix the extension cable and the external shield to the shield terminal.
• Connect the extension cable to the terminals of the transmitter (see Fig. 6.9 and Tab. 6.3).
6.3.4
Connection of the Transducer Cable to the Junction Box
• Remove the left blind plug for the connection of the transducers (see Fig. 6.5).
• Open the cable gland of the tranducer cable (see Fig. 6.4).
• Push the extension cable through the cap nut and the compression part.
• Cut the external shield and brush it back over the compression part.
• Screw the gasket ring side of the basic part tightly into the housing.
• Insert the transducer cable into the housing.
• Fix the cable gland by screwing the cap nut onto the basic part.
• Connect the leads to the terminals of the junction box (see Fig. 6.8 or Fig. 6.9 and Tab. 6.5).
Attention!
The external shield of the extension cable must not have electrical contact to the junction box. There-
fore, the extension cable must remain completely insulated up to the shield terminal.
Tab. 6.4: Terminal assignment (extension cable, KL2)
terminal
connection
TV
white or marked cable (core)
TVS
white or marked cable (internal shield)
TRS
brown cable (internal shield)
TR
brown cable (core)
shield terminal external shield
Attention!
For good high frequency shielding, it is important to ensure good electrical contact between the exter-
nal shield and the cap nut (and the housing).
Tab. 6.5: Terminal assignment (transducer cable, KL1)
terminal
connection
TV
transducer
(core)
TVS
transducer
(inner
shield)
TRS
transducer
(internal
shield)
TR
transducer
(core)
Summary of Contents for FLUXUS WD100
Page 1: ...User Manual UMFLUXUS_F5WDV1 1EN Ultrasonic Flowmeter for Water FLUXUS WD100 FLUXUS WD200...
Page 4: ...FLUXUS WD100 WD200 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 8: ...FLUXUS WD100 WD200 Table of Contents 8 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 104: ...FLUXUS WD100 WD200 D Declarations of Conformity 104 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 105: ......
Page 106: ......