6 Installation of the Transmitter
UMFLUXUS_F5WDV1-1EN, 2016-04-08
31
6.4
Connection of the Power Supply
• Remove the right blind plug for the connection of the power supply (see Fig. 6.10).
• Prepare the power cable with an M20 cable gland.
• Push the extension cable through the cap nut, the compression part and the basic part of the cable gland (see Fig. 6.11).
• Insert the power cable into the housing (see Fig. 6.10).
• Screw the gasket ring side of the basic part tightly into the housing.
• Fix the cable gland by screwing the cap nut on the basic part (see Fig. 6.11).
• Connect the leads to the terminals of the transmitter (see Fig. 6.10 and Tab. 6.6).
Attention!
The degree of protection of the transmitter will only be guaranteed if the power cable fits firmly and
tightly in the cable gland.
Fig. 6.10: Connection to the transmitter
Tab. 6.6: Terminal assignment - Connection of the power supply
terminal
connection AC
connection DC
PE
earth
earth
N(-)
neutral
- DC
L(+)
phase
+ DC
Fig. 6.11: Cable gland
outputs power supply
cap nut
compression
part
basic part
gasket ring side
of the basic part
Summary of Contents for FLUXUS WD100
Page 1: ...User Manual UMFLUXUS_F5WDV1 1EN Ultrasonic Flowmeter for Water FLUXUS WD100 FLUXUS WD200...
Page 4: ...FLUXUS WD100 WD200 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 8: ...FLUXUS WD100 WD200 Table of Contents 8 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 104: ...FLUXUS WD100 WD200 D Declarations of Conformity 104 UMFLUXUS_F5WDV1 1EN 2016 04 08...
Page 105: ......
Page 106: ......