Example:
P
SV
; Trigger pressure safety valve 6 bar (appendix)
(From order specification <= nominal pressure unit)
P
E
; final pressure 5.4 bar
Safety valve, code letter DGH
P
SV
x 0.9 [P
SV
>= 3 bar]; P
SV
- 0.3 bar [P
SV
< 3 bar]
Safety valve, code letter H
P
SV
- 0.5 bar [P
SV
= 3 bar]
(From order specification)
P
A
; Operating pressure 1.2 bar (configurable range by unit type)
P
A+
; Upper operating pressure tolerance 0.2 bar (default)
P
A-
; Lower operating pressure tolerance 0.2 bar (default)
(From order specification)
P
+
; Positive pressure 0.3 bar (default, recommended)
P
0
; Displayed value, message: P
A
- P
A-
- P
+
= 1.2 - 0.2 - 0.3 = 0.7 bar
(e.g.: = P
static
+ P
steam
+ P
dynamic = 0.7 bar
)
Main switch on;
SPC terminal with
main menu
on;
Fields and messages
with backlighting
are active.
- Menu 2:
Module
extension option
required;
- Menu 3:
Check, change
date, time
- Menu 4:
Check, change
language
- Menu 5:
Not
possible, not necessary;
- Menu 8:
Defaults
can be still changed
after start or as
required:
- Menu 8-1-1:
Application to
change P
e
, P
A
- Menu 8-2-2: Can be
switched off/on if
drainage exists;
- Menu: 8-3-1: Install
on request, then
enable;
- Menu 8-4-1...17:
Group error message
assignments; enable/
disable
on request;
- Menu 9:
- Menu 9-1: Please note;
- Menu 9-5: Input, select
nominal capacity;
- Menu 9-6: Execute;
- Menu 9-7: Execute;
- Menu 9-8: Check,
change;
- Menu 9-9: Operating
range determined,
execute.
Example:
Actual pressure 1.4 bar
Duopump unit; pumps, valves not ON.
Vessel content 0 %, error min. priming
water ON (error no.: 19; 10).
top-up valve 230v, self-monitoring, ON;
No impulse water meter, top-up time < 1 minute.
Gas sensor enabled, degasification mode normal
(Degassing not ON due to min. priming water).
Example:
Summer time is ON
date: 23.10.2010.
Time:
18.00 hours,
12 minutes, 57 seconds.
Line below:
Functional assignment for
sensor buttons.
Change menu
Date, time
Werkingsindicator
Start
Pressure
settings
Turkish
Operational
calibration
Save configuration
on SD
ID Vessel
ID Vessel
Example:
The nominal volume
(see section 5.2) is
shown on the vessel
label or SPC ID sticker.
This corresponds to the
vessel capacity with the
letter A, B or C.
For example:
A-200
B-200
C-200
(....)
Read
manual
Operating
Menu
Service
menu
Order number
Unit
information
Version
information
Start
Maintaining
Error list
Operating hours
Top-up,
overflow spill
Start
menu
Configuration
menu
Loginmenu
Degassing
Manufacturer,
supplier
(traceability)
Unit, vessel,
vessel calibration
(test)
Control unit,
software, hardware
(traceability)
Date: Start of
commissioning,
vessel calibration
(statistics)
See:
Maintaining
Error history, no longer active
errors, error no., date, time
(analysis)
(Statistics)
Quantities,
times
(statistics)
Degassing
procedure
ON, OFF
(Test cycle ON,
see 8-5 -2)
Distribution of
sleep intervals to
weekdays (next
page)
Gas sensor, sensor
connection array
required (optional)
Activated
Controlled
Standby
Normal
Operating
pressure menu
Closing
times
Language
menu
Error
message
Pressure
(....)
Phase
monitor
Date/ Time
menu
Sensors
valves
Minimum
pressure limiter
Data transfer
menu
Level
Top-up
Drain
Fast
Pressure
Operating
pressure
SPC terminal
SD-kaart
German
Main menu
7.3 Overview menu options
Fig. FM.038.V02.15
ENG