TemplateA4_v20130506
14
16 17
r e
fi
l l / dra in
1
2
5A
5A
30
250
VDC
VAC
ohm ic l oa d
42 43
45 46
41
44
V1
V1.1
N
N
19 20
18
M3/3.1 V3/3.1
r e
fi
l l / dra in
N
L1
M1
m a i n s supply
400V 50/60Hz
h
ig
h
v
o
lt
a
g
e
L1
L1
N
L1 L2 L3
L1 L2 L3
23 23
23
+
2
4
V
/
s
ig
n
a
l
+
s
ig
n
a
l
2
3
4
5
_
+
2
4
V
/
s
ig
n
a
l
+
6
7
+
2
4
V
/
s
ig
n
a
l
+
+
2
4
V
/
s
ig
n
a
l
+
1
8
9
p w m
10 11
m pl
12 13 14
28
29 30
31 32
33 34
35 36 37
27
t c
gs
d rs
ps
fa u lt
3
4
B
A
+
24V
_
2
1
2
1
2
1
2
1
1
2
1
2
1
2
p
re
s
s
u
re
n
iv
e
a
u
s
ig
n
a
l
_
s
ig
n
a
l
_
C
o
m
NO
NC
n i vea u
p r essure
0
-1
0
V
0
-1
0
V
C
o
m
C
O
M
R
S
2
3
2
=
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
a c c essory
opt ion
e
x
tr
a
-l
o
w
v
o
lt
a
g
e
sen sors
e
x
tr
a
-l
o
w
v
o
lt
a
g
e
5A
5A
30
250
VDC
VAC
ohm ic l oa d
o
p
ti
o
n
d a t a
opt ion
C
O
M
R
S
4
8
5
1
2
SPC
t er m i na l
p
Flamco
09729 0810
/ 2 / 3
/ 1
48 49
47
V2/2.1
N
L1
SPCx-h w -1-1
Terminal plan SPCx-hw-1-1:
Fig. FM.013.V01.15
Read the manual!
Bedienanweisung lesen!
ATTENTION:
Despite disconnecting from
the main power line,
some terminals may still be energised at 250V AC
: 12; 13; 14; 16; 17!
ACHTUNG:
Trotz Netztrennung kann,
an den Klemmen: 12; 13;
14; 16; 17, eine Spannung
von 250VAC anliegen!
+
2
4
V
/
s
ig
n
a
l
+
s
ig
n
a
l
2
3
4
5
_
+
2
4
V
/
s
ig
n
a
l
+
6
7
+
2
4
V
/
s
ig
n
a
l
+
+
2
4
V
/
s
ig
n
a
l
+
1
8
9
p w m
10 11
m pl
12 13 14
28
29 30
31 32
33 34
35 36 37
27
t c
gs
d rs
ps
fa u lt
3
4
B
A
+
24V
_
2
1
2
1
2
1
2
1
1
2
1
2
1
2
p
re
s
s
u
re
n
iv
e
a
u
s
ig
n
a
l
_
s
ig
n
a
l
_
C
o
m
NO
NC
n ivea u
p ress u re
0
-1
0
V
0
-1
0
V
C
o
m
C
O
M
R
S
2
3
2
=
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
G
N
D
a c c es sory
op t ion
e
x
tr
a
-l
o
w
v
o
lt
a
g
e
s en s ors
e
x
tr
a
-l
o
w
v
o
lt
a
g
e
5A
5A
30
250
VDC
VAC
oh m ic loa d
o
p
ti
o
n
d a t a
op t ion
C
O
M
R
S
4
8
5
1
2
SPC
t er m in a l
16 17
r e
fi
ll / d ra in
1
2
5A
5A
30
250
VDC
VAC
oh m ic loa d
42 43
45 46
48 49
41
44
47
V1
V1.1
V2/2.1
N
N
N
19 20
18
M3/3.1 V3/3.1
r e
fi
ll / d ra in
N
L1
M1
M2
m a in s su pply
400V 50/60Hz
h
ig
h
v
o
lt
a
g
e
L1
L1
L1
N
L1 L2 L3
L1 L2 L3
23 23
23
/ 2 / 3
/ 1
L1 L2 L3
26 26 26
SPCx-h w -1-2
p
Flamco
09825 0810
/ 2 / 3
/ 1
Terminal plan SPCx-hw-1-2:
Read the manual!
Bedienanweisung lesen!
ATTENTION:
Despite disconnecting from
the main power line,
some terminals may still be energised at 250V AC
: 12; 13; 14; 16; 17!
ACHTUNG:
Trotz Netztrennung kann,
an den Klemmen: 12; 13;
14; 16; 17, eine Spannung
von 250VAC anliegen!
Fig. FM.014.V01.15