MONITORING A RETEMATIC NETWORK
This chapter provides information to monitor the status of the ReteMatic network.
Connect a PC to the ReteMatic Head Unit or to a switch that is connected to the ReteMatic Head Unit,
the PC used must be configured with an IP address in the same subnet of the one assigned to the unit.
Using an internet browser, connect to the IP address assigned to the unit and provide the credentials for
the authentication (see “Authentication Page” on page 11). The browser must have the JavaScript
functionality enabled in order to make the Web application work properly
In the main page of web interface (Figure 10) look for the “
Available Connections
” frame: it contains a
list of all nodes currently active on the ReteMatic network. Each node is identified by its Device ID, its
MAC address and a value that represent the quality of the connection between the node and ReteMatic
Head Unit. This value does not represent the actual throughput of the connection, but it is an indication
of the status of the link: the higher the values, the better the connection. Roughly, values of 50 or better
indicate a good and stable connection, but you can have properly working connections also with lower
values
Figure 10 - An example of monitoring page of ReteMatic network