background image

fitech ag

 Switzerland 

Operating Manual 

page 3

  

 

fitech

-Flowmeter 

 

 

 

Applications of the 

fitech

-Flowmeter 

 

The 

fitech

-Flowmeter  is  used  for  measuring  the  flow  of  high-viscous,  pasty  products. 

Depending on the product to be measured, different size nozzles may be used, however, the 

standard-size nozzle has a 4 mm hole, H7.  

 

  
 

Introduction to the Operating Manual 

 

This  Operating  Manual  includes  information  on  the  safety,  use  and  maintenance  re-

quirements of the 

fitech

-Flowmeter.  

It is to be thoroughly studied and understood by the operator of the equipment as well as all 

staff using the 

fitech

-Flowmeter. Specific instructions and training must be provided in order 

to ensure a safe operation of the equipment.  
The Flowmeter has been built according to the latest technical standards in all respects, also 
its  safety.  The  use  of  the  measuring  equipment,  although  rather  simple,  may  cause    

grievous  physical  injury  to  personnel  working  with  it,  should  operating  instructions  not  be 

followed. 

Fitech

  excludes  any  responsibility  for  damages  or  injuries  whatsoever  that  may 

result  from non-compliance  with or non-comprehension  of these  instructions.  Furthermore, 

all  requirements  by  the  operator  of  the  plant  himself  and  any  locally  applicable  statutory 

laws, regulations, etc. that might be applicable must be adhered to.  
Please  note  that  this  Operating  Manual  does  not  provide  instructions  on  repairs  that  go 

beyond maintenance of the plant.  
 

 

 

Safety, operation and maintenance 

 

CAUTION:  Regulations of use of laboratory equipment etc., labour laws in force 

at the place where the equipment is used must be strictly adhered to!  
CAUTION: The Flowmeter is operated with compressed air. All necessary caution 

when using it is to be employed! 
Protect  your  body  against  harmful  incidents,  your  eyes  with  the  appropriate 

safety glasses or goggles, the hands with the appropriate safety gloves, etc.   
CAUTION: All required safety measures must be in place during the entire use of 

the equipment! 
CAUTION: Ensure no pre-set limits are exceeded! 

 

Summary of Contents for PM 43

Page 1: ...L for the fitech Flowmeter PM 43 Flow measuring equipment Type PM 4300 29 N Equipment No 13 780 29 Prior to the first use please follow the instructions under the CLEANING section of this Operating Ma...

Page 2: ...hapters Subjects page Applications of the fitech Flowmeter 3 Introduction to the Operating Manual 3 Safety operation and maintenance 3 Place of operation 4 Operation 4 Preparation for measurements 4 M...

Page 3: ...to personnel working with it should operating instructions not be followed Fitech excludes any responsibility for damages or injuries whatsoever that may result from non compliance with or non compreh...

Page 4: ...area thoroughly and implements additional safety measures if necessary Operation Prior to its first operation the following points must be checked All screwed connections are fastened tightly either m...

Page 5: ...e an air leak CAUTION The parts mentioned nozzle nozzle carrier measure and pressure cylinders are precision parts with very fine threads When screwing together take care not to set threads canted aga...

Page 6: ...s especially the pressure plate Clean the threads of the parts including the pressure cylinder thoroughly It is important however that the threads are greased again prior to remounting the parts Use o...

Page 7: ...cooling jacket 90 40 50 4 Nozzle carrier 27 60 M12 5 Nozzle 2 6 mm H7 Nozzle 4 mm H7 6 Pressure plate B 39 9 21 7 Pressure gage R 0 to 6 bar 0 6 160 8 Hand valve VHB 3 2 9 Pressure regulator R A 1000...

Page 8: ...fitech ag Switzerland Operating Manual page 8 fitech Flowmeter...

Reviews: