Chapter 2 | Getting Started 

Icon 

Description 

 

Electrode Good Icon: Indicates the pH 

electrode condition is good, based on 

the last saved calibration data and 

resulting slope value.  

 

Electrode Warning Icon: Indicates the 

pH electrode condition is fair or bad, 

based on the last saved calibration data 

and resulting slope value.  

 

Computer Export Icon: Indicates meter 

is actively exporting measurement data 

or calibration data to a computer.  

 

Printer Export Icon: Indicates meter is 

actively exporting measurement data or 

calibration data to a printer.  

 

2.5 Meter Connections 

 

 

Input 

Function 

Power  Universal power supply 

GND 

Ground 

Export  Connection to printer or computer 

ATC 

Connection to ATC temperature probe 

BNC 

Connection to pH or ORP (redox) electrode 

 

2.6 Electrode Information 

The accumet AB315 pH/mV meter is compatible with pH 
electrodes and ORP (redox) electrodes with a BNC 
connector. The accumet AB315 pH/mV meter can be 
purchased in a meter only configuration (purchase 
electrode separately) or kitted with different electrodes.  

Refer to the electrode instructions for specific care and 
maintenance procedures. The following are general 
recommendations for electrode preparation.  

 

Remove the protective cap/bottle from the 
electrode and save for storage.  

 

Rinse any salt deposits off the electrode using 
distilled or deionized water. 

 

If the electrode is refillable, uncover the fill hole and 
add filling solution to the electrode up to the fill 
hole. The fill hole should remain open when the 
electrode is in use. 

 

Soak the electrode in storage solution when first 
preparing the electrode and when the electrode is 
not in use. 

 

Connect the electrode to the meter. 

2.7 Meter Startup 

Sequence 

When the meter is powered on, it displays a set of startup 
screens, starting with all segments lit screen, followed by 
the meter info screen and then the meter self-test screen.  

The meter info screen shows the meter model number and 
current software revision.  

After the meter info screen, the meter performs a series of 
internal self-tests to verify that the meter is operating 
correctly and then the self-test results are shown. 

Finally, the meter proceeds to the main measure mode.  

 

 

Summary of Contents for accumet AB315

Page 1: ...Operations Manual Electrochemistry Meters 68X002124 Revision 01 September 2021 accumet AB315 pH mV Meter User Manual...

Page 2: ......

Page 3: ...3 1 Setup Menu Scrolling 8 2 3 2 Setup Menu Value Changes 8 2 3 3 Mode Shortcut Key 8 2 3 4 Date and Time View Shortcut Key 8 2 4 Display Overview 9 2 5 Meter Connections 10 2 6 Electrode Information...

Page 4: ...19 3 2 16 Sleep Mode 19 3 2 17 Clear Data 19 3 2 18 Factory Reset 20 Chapter 4 21 Calibration 21 4 1 pH Calibration 21 4 1 1 pH Calibration Overview 21 4 1 2 pH Calibration Procedure 21 4 1 3 pH Calib...

Page 5: ...28 7 2 Meter Dimensions 29 7 3 Warranty 29 7 3 1 Return of Items 29 Chapter 8 30 Regulatory Compliance 30 8 1 European Union 30 8 2 Product Safety 30 8 3 Electromagnetic Compatibility 30 8 3 1 FCC Sta...

Page 6: ...ol in the context of a Note indicates to follow the manufacturer specified instructions notes and requirements set out in the instruction manuals CAUTION Before using or maintaining this product pleas...

Page 7: ...US Japan Euro UK Singapore Australia New Zealand and China wall plug plates is included with the meter This universal power adapter is specifically for use with this meter Use of other power adapters...

Page 8: ...etting Press to save a setting in the Setup Menu Press to accept a calibration point in the Calibration mode Press to power on the meter When the meter is on press to turn the backlight off or on When...

Page 9: ...Icon Indicates meter is in the Setup Menu and viewing the data log or calibration log Log Saved Icon Indicates meter is actively saving data to the data log or calibration log Continuous Icon Indicate...

Page 10: ...separately or kitted with different electrodes Refer to the electrode instructions for specific care and maintenance procedures The following are general recommendations for electrode preparation Remo...

Page 11: ...d data logs and calibration logs to the selected export device 4 Temperature Calibration or Manual Temperature Input When an ATC probe is connected use the Temp Calibration menu to perform a temperatu...

Page 12: ...key to view the display log 3 2 1a Viewing the Data Log Press the Enter key to view the display log For the data log press the or key to scroll through the data log points Scroll through data log poin...

Page 13: ...calibration log data Press key Press key Press key Press key Press key If desired press the Log Export key to export the individual calibration log being viewed Press the Menu key to return to the mai...

Page 14: ...he Setup Menu list until the Temp Calibration item is shown The temperature value will blink indicating the reading from the ATC probe is being measured Once the reading is stable the value will stop...

Page 15: ...ress the Enter key to save the change 3 2 6 pH Resolution Set the displayed pH resolution as 0 1 or 0 01 pH units Press the or key to scroll through the Setup Menu list until the pH Resolution item is...

Page 16: ...d In the Timed measure mode the measurement values are continuously updated on the display Measurements are automatically saved to the data log and exported at the selected time intervals from 5 secon...

Page 17: ...ly increase b Press the key to decrease the alarm value by one hour Press and hold the key to quickly decrease Press the Enter key to save the change 3 2 11 Temperature Units Set the temperature units...

Page 18: ...and hold the key to quickly increase b Press the key to decrease by one day Press and hold the key to quickly decrease Press the Enter key to save the change The year value will flash Press the or ke...

Page 19: ...the or key to set the audio mode Press the Enter key to save the change 3 2 16 Sleep Mode Set the sleep mode on or off When the meter sleep mode is on the meter will enter sleep mode when no keys are...

Page 20: ...ta logs calibration logs and settings and return the meter to its factory default state Press the or key to scroll through the Setup Menu list until the Factory Reset item is shown Press the or key to...

Page 21: ...s to be manually adjusted use the or key to edit the value of the pH buffer at its measured temperature To eliminate temperature errors associated with the pH electrode use an automatic temperature co...

Page 22: ...ion The active Calibration Buffer Set is shown Rinse the pH electrode and ATC probe and place into the pH 4 01 buffer Wait for the pH value to stabilize Once the reading is stable press the Enter key...

Page 23: ...11 12 14 40 1 69 4 03 6 84 9 07 11 99 50 1 71 4 06 6 83 9 01 11 73 60 1 72 4 09 6 84 8 96 11 50 70 1 74 4 12 6 85 8 92 11 30 80 1 77 4 16 6 86 8 89 11 13 DIN Buffer Set Temp C pH 1 09 Buffer pH 3 06...

Page 24: ...Calibration The thermistor sensor used for automatic temperature compensation and measurement is both accurate and stable so frequent calibration is not required When an ATC probe is connected to the...

Page 25: ...are automatically saved to the data log and exported at the selected time intervals from 5 seconds to 60 minutes the entire time the meter is in the measurement mode 5 2 pH and ORP Measurements Rinse...

Page 26: ...Baud Rate 9600 bps Data bits 8 Parity None Stop bits 1 Flow Control None 5 5 1 Remote Commands Remote commands allow the meter to be interfaced with computer software like LIMs and HyperTerminal The r...

Page 27: ...pH buffers and pH electrode o Replace pH buffers o Clean and condition pH electrode o Replace pH electrode as needed 6 2 Measurement Troubleshooting Reading is unstable slow to stabilize Clean electr...

Page 28: ...t Up to 5 C up to 9 F Features Display 5 backlit LCD Time and Date Yes Read Types Continuous Auto Read Timed Timed Interval 5 seconds to 60 minutes Hold Function Yes Data Log 500 data sets with time a...

Page 29: ...ired on a charged basis The warranty on your meter shall not apply to defects resulting from Improper or inadequate maintenance by customer Unauthorized modification or misuse Operation outside of the...

Page 30: ...ironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicat...

Page 31: ...entsorgt werden Mehr Informationen ber die Einhaltung dieser Anweisungen durch Thermo Scientific dieVerwerter und Hinweise die Ihnen n tzlich sein k nnen die Thermo Fisher Scientific Produkte zu iden...

Page 32: ...13 620 19 accumet ORP electrode 13 620 81 accumet meter attached electrode stand 13 637 671 accumet AB315 and AB330 meter replacement universal power cord 110 240V 13 637 010 accumet AB315 and AB330...

Reviews: