INSTALLATION INSTRUCTIONS
9
Installation options
There are two different ways your dryer can be positioned. Freestanding or inverted
and mounted on a wall.
Freestanding
The dryer stands on the floor and can easily be moved into position.
1
Move the dryer into the desired position. Do not lift the dryer by the top panel.
2
Have a minimum clearance on all sides of at least 20mm.
3
Have a minimum clearance at the rear of 75mm.
The spacers from the accessory wall mounting kit
can be used to set this distance.
4
Install the dryer on a stable and level floor.
Freestanding venting options
Note: the vent system should be less than
two metres long with no more than three 90⁰ bends.
Before a rear venting option is installed the dryer
must be changed from the front venting factory
setup. Remove the outlet grille from the front
left-hand side and replace with the outlet cover
from the rear left-hand side. These covers should be
gently pried at the sides to prevent damage.
External venting
The dryer is vented with a kit that can be positioned
to remove air to the side.
The dryer is vented directly through the wall using
a ducting kit in combination with the duct adaptor
supplied with the dryer.
The dryer is vented through a window using a
ducting kit in combination with the duct adaptor
supplied with the dryer. This requires the dryer to
be a minimum distance of 140mm from the wall to
ensure the ducting is not restricted with tight bends
or can be crushed.
Internal venting
Front venting is the only recommended option for
venting into the room. The dryer is set up for front
venting when it leaves the factory.
Note: where possible all efforts should be made to
vent the dryer externally to avoid moisture build up
around the dryer.
External venting with kit part
number PD-F0408
External venting with kit part
number PD-SVHCW4
External venting with kit part
number PD-DK4W