7
Flush venting
The dryer is vented through a hole in the wall, using a
galvanised metal pipe or flexible hose. This is suitable for floor
and wall mounted dryers installed against an outside wall.
Kit Vent External 400 mm Hose Part No. 460754
Movable venting
The dryer is vented using a flexible hose through a hole in the
wall. This allows the dryer to be moved from the wall slightly.
Suitable for floor mounted dryers only.
Flexible Hose 2 m
Part No. 503858
Window venting
A flexible hose is used to vent the dryer through a window.
Maximum hose length is 2 metres.
Flexible Hose 2 m
Part No. 503858
Flexible Hose 0.4 m
Part No. 460601
Venting duct
The dryer is vented using an extendible duct that allows venting
to a window or through an existing wall vent. The duct can be
used with a flexible hose. Specially suitable for inverted dryers.
Venting Duct Kit
Part No. P6451
Flexible Hose 2 m
Part No. 503858
Internal venting
A deflector is included with the dryer (Part No. 460822P).
If external venting is not at all possible the deflector must be
fitted. This screws on to the back of the dryer over the exhaust
outlet. The outlet of the vent deflector must be clear of any
obstructions to ensure normal and safe operation. The outlet
should be directed towards the middle of the dryer (as in Fig.9).
Note: all efforts should be made to vent the dryer externally, if
possible, to avoid moisture build up in the area around the dryer.
Note: not all parts may be available in all countries.
Fig. 9 Internal venting
Installation – AeroSense™ and AeroLogic™ dryers
Fig. 6 Flush venting
Fig. 7 Movable venting
Fig. 8 Venting duct