Installation Instructions
Page 74 Panda AGT-DC 4000 PVMV-N s00670 - Chapter E: Installation Instructions
29.12.04
Antifreeze
The
antifreeze
concentration must be regularly checked in the interests of safety. The antifreeze
solution supplied from the factory provides protection to -15°C. If lower temperatures are occasio-
ned during transportation or storage, then the coolant must be drained. The cooling system is,
however, so arranged that the draining of the coolant is only possible in the assembled state,
when air under pressure is blown into the system. Air pressure of approx. 0.5b suffices, in order
to blow out the water.