Maintenance Instructions
29.12.04
Panda AGT-DC 4000 PVMV-N s00670 - Chapter C: Maintenance Instructions Page 43
C.5 Exchange the air filter
Open the air suctin housing by loosen the
six hexagon head screws on the frame
cover.
Remove the cover.
Change the air filter mat and close the
cover again.
Subsequently, close the cover again
firmly.
C.6 Additional maintenance
Furthermore in addition to the standards checks according to the manual following points of the
generator have to be checked:
• automatic shut down of the generator in case off high heating temperature This shall be done by
disconnecting the thermo-switch of the heat sink. Next to the rectifier you will find a 2-pole con-
nector. If you disconnect this connector from the opposite socket, the generator shall shutdown
– or, when the generator is not running you will get a signal on the panel.