Installation Instructions
Page 64 Panda AGT-DC 4000 PVMV-N s00670 - Chapter E: Installation Instructions
29.12.04
E.2 Voltage Control System
The VCS control is used for the adjustment of the number of revolutions of the engine and thus
the voltage of the generator. It belongs to the accessories and is externally attached.
ATTENTION!
The cable for the measuring voltage must be attached directly at the battery, and may not atta-
ched to the output of the electric rectifier. By the voltage drop between generator and battery the
accurate voltage can only recieved direct at the battery. A false link can lead to damage the bat-
tery!
06
03
04
01
05
07
02
09
08
01. Voltage sense (+) (24V)
02. Voltage sense (-) (24V)
03. Actuator (+)
04. Actuator (-)
05. Battery voltage supply (+)
06. Battery voltage supply (-)
07. Stop line (regulates the actuator back at shut-off
the device)
08. Terminal shunt measurement 0mV DC (-)
09. Terminal shunt measurement608mV DC (+)