![Fischer Panda AGT 4000 PVMV-N Handbook Download Page 75](http://html1.mh-extra.com/html/fischer-panda/agt-4000-pvmv-n/agt-4000-pvmv-n_handbook_2294280075.webp)
Installation Instructions
29.12.04
Panda AGT-DC 4000 PVMV-N s00670 - Chapter E: Installation Instructions Page 69
8. Main terminal clamp - allocation:
1: Battery plus (+)
2: Battery minus (-)
3: Input temperature failure
4: Input charge control
5: Input oil pressure failure
6: Input generator voltage 1
7: Input generator voltage 2
8: Output pre-glow
9: Output fuel pump
10: Output starter motor
11: Output VCS-ON (voltage control for VCS)
12: Output operating voltage, maximum permissible load: 0,2A
9. Terminal clamp for battery monitor - allocation:
13: Battery minus (-)
14: Input for battery monitor
The potential-free contact of a battery monitor can be connected to these two terminals, the star-
ting sequence occurs automatically if the contact closes.
8
9
10
11
12
14
13
Summary of Contents for AGT 4000 PVMV-N
Page 64: ...Generator Failure Page 58 Panda AGT DC 4000 PVMV N s00670 Chapter D Generator Failure 29 12 04...
Page 90: ...Appendix Page VIII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...
Page 94: ...Measurements Page XII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...