Installation Instructions
10.5.11
Panda 8000-42NE PVMV-N.R01 - Kapitel/Chapter 5: Installation Instructions Seite/Page 57
5.2.4 Connection to Starter Battery-Block
An own separate starter battery must be installed for the generator.
The positive cable (+) of the battery is attached directly at the solenoid switch of the starter motor (position 1). The
negative cable (-) of the battery is attached underneath the starter motor at the engine mount (position 2).
NOTE:
Panda Generators Panda 6000 and higher normaly provided
with an alternator/dynamo to charge the starter battery. At
generators without alternator/dynamo it is needed to charge
the starter battery with an external battery charger.
ATTENTION!
It must be guaranteed that first the cables are attached at the
generator and then at the battery.
ATTENTION!
Make shure that the voltage of the starter battery fits to the start
system voltage
f.e. 12 V starter battery for a 12 V start system
.e. 24 V starter battery for a 24 V start system (2 12 V batterys in a row)
NOTE:
To avoid large voltage drops the battery should be installed as
near as possible to the generator. The positive terminal of the
battery is attached at the red cable, the negative pole at the
blue cable.