![Fischer Panda 15000i PMS Manual Download Page 79](http://html1.mh-extra.com/html/fischer-panda/15000i-pms/15000i-pms_manual_2294291079.webp)
Maintenance Instructions
4.5.16
Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 79
necessary to refill oil. See „Refilling oil“ on page 2.
• with 150 operating hours or more the oil should be changed (See your generators’ service table)
• if the oil-level is under the minimum mark by less than 50h, there might be a technical problem! In that case, we
recommend going to a shop or a Fischer Panda service point.
• if the oil is cloudy or even „creamy“, coolant might have mixed with the oil. See a garage or a Fischer Panda service
point immediately.
7.6.1 Refilling oil
You require:
Engine oil
1. Check oil-level as described under section 7.6, “Checking oil-level,” on page 77.
2. Oil dipstick is pulled out of the check rail.
3. Open the oil filler cap.
4. Fill in oil (approx. 1/2 litre) and wait for about 2 min. so this it can flow into the oil pan.
5. Wipe off the oil dipstick and put it into the check rail.
6. Pull the oil dipstick out of the check rail and check the oil-level. See section 7.6, “Checking oil-level,” on page 77.
If oil-level is still too low (under 2/3): repeat steps 4-6.
7.6.2 After the oil level check and refilling the oil
• Put the oil dipstick back into the check rail.
• Close the oil filling cap.
• Remove potential oil stains and splashes from the generator and surroundings.
• Close the generator casing.
• Remove lock against accidental generator start.
Summary of Contents for 15000i PMS
Page 10: ...Seite Page 10 Kapitel Chapter 2 4 5 16 Leere Seite Intentionally blank...
Page 70: ...Installation Instructions Seite Page 70 Kaptitel Chapter 5 Installation Instructions 4 5 16...
Page 112: ...Tables Seite Page 112 Kaptitel Chapter 9 Tables 4 5 16...
Page 176: ...Seite Page 176 Kapitel Chapter 16 Annex 4 5 16 Leere Seite Intentionally blank Annex...