Installation Instructions
4.5.16
Kapitel/Chapter 5: Installation Instructions - Seite/Page 61
Fig. 5.7.3.2-2: Tilted position 45 degrees
Tilted position 45 degrees - Fig. 5.7.3.2-2
The water level is now at the same height as the critical point at the exhaust elbow. If the ship is sailed in a tilted
position of 45 degrees with an installation like this, the ingress of cooling water into the combustion chamber is
inevitable. Irreparable damages are pre-programmed.
B) Installation distance between waterlock and the generator’s center line 1000 mm
Fig. 5.7.3.2-3: waterlock, 1000 mm next to center line
Fig. 5.7.3.2-4: Tilted position 30 degrees
Tilted position 30 degrees - Fig. 5.7.3.2-4
The water level and the critical point at the exhaust elbow are at the same level now. If the ship is sailed in a tilted
position of 30 degrees with an installation like that, the infiltration of cooling water into the combustion chamber is
inevitable. Irreparable damages are pre-programmed.