Warnings and error messages
4.5.16
Kapitel/Chapter 15: Warnings and error messages - Seite/Page 173
15.3.1 How to get to the error memory of the iControl2 Panel?
The error memory is easily accessible via the setup menu of the control panel which is open to every user.
The setup menu can be accessed as usual:
• To access the setup menu, please press the key "Cursor Down" directly after switching on the control while the
panda bear is displayed.
• Now you can see the setup menu and its menu items.
• You can navigate through the menu viy the keys
• „Cursor-Up“ und „Cursor-Down.
• The selected menu item is marked by two *symbols.
• The start/stop key is used for validation in the setup menu. If you select and validate the row marked by the * by
actuating the start/stop key, you will access the selected sub-menu.
• To display the error memory please select the menu item
Error mem.
15.3.2 How are stored errors displayed?
The errors are displayed in the plain text. The error is preceded by the operating hour when the error occurred. The
fault having the highest operating hour will be displayed in the first row. Older error entries are displayed in the rows
below in descending order of the operation hour. If the memory contains already six errors, the oldest entry is
deleted.
Expample for displaying an error entry:
3045.2h COMMUNICATION
This means: In operating hour 3045.2 an error in the bus communication has occurred.
15.3.3 How do I exit the error memory after having read the entries?
You can return to the standby page via the start-stop-key.
15.3.4 Can I delete the error memory?
No, it is not possible to delete the error memory.
15.3.5 Where are the errors stored?
In the EEPROM of the panel or in the storage of the control board?
The errors are stored in the EEPROM of the control board. The control panel only displays the errors which are
stored there. If, for service reasons, the control panel has to be exchanged, the entries remain in the error memory.
15.3.6 In which language are the stored errors displayed?
The stored errors are displayed in the language which is set in the control panel. This can be English or German
depending on your settings.
Summary of Contents for 15000i PMS
Page 10: ...Seite Page 10 Kapitel Chapter 2 4 5 16 Leere Seite Intentionally blank...
Page 70: ...Installation Instructions Seite Page 70 Kaptitel Chapter 5 Installation Instructions 4 5 16...
Page 112: ...Tables Seite Page 112 Kaptitel Chapter 9 Tables 4 5 16...
Page 176: ...Seite Page 176 Kapitel Chapter 16 Annex 4 5 16 Leere Seite Intentionally blank Annex...