Installation Instructions
Seite/Page 80 - Kaptitel/Chapter 5: Installation Instructions
16.1.15
5.9.3.4 Underfloor installation of radiator
Please note:
• Minimum distance to vehicle floor: 100 mm.
• Minimum distance to ground: 1/2 radiator width
• Min. distance to gas exhaust (heat and dirt source): 500 mm.
• The max. permissible vehicle height must not be exceeded.
Note:
Fischer Panda does not recommend underfloor
installation. The radiator can quickly become dirty. Rock
impacts can result in damage to the radiator. The
efficiency of the radiator will drop due to thermal short-
circuiting. The radiator may have to be dimensioned
larger to compensate.
Attention:
The installation position of the radiator (upside down or
not) depends on the airflow direction of the fan. The
airflow must be always from the vehicle side through the
radiator to the ground.
Fig. 5.9.3.4-1: Underfloor installation of radiator
Fig. 5.9.3.4-2: Underfloor installation of radiator