Maintenance Instructions
Seite/Page 134 - Kaptitel/Chapter 7: Maintenance Instructions
16.1.15
7.15 Replacing the Oil Pressure Switch
NOTE:Representative procedure
The described procedure is representative for Fischer Panda
generators. The original location of the item must be taken
from the generator description of this manual. All
replacements and repairs should be done by a trained
person.
ATTENTION!
Ensure that the generator cannot be started up
accidentally. Remove battery main switch.
For part numbers, refer to the spare parts catalogue.
Fig. 7.15-1: Oil pressure sensor
1. Open both connectors (01) on the oil pressure switch.
2. Pull off rubber cap (02).
Fig. 7.15-2: Oil pressure sensor
3. Loosen and remove oil pressure switch 4B4 using a
wrench with W.A.F. of 29 mm. A large piece of cloth or
absorbent tissue must be placed under the connection to
prevent escaping oil from running into the capsule.
4. To reinstall, reverse the order of steps. The switch is fitted
with a tapered thread and requires no special seal.
01
02
29