25.3.2003
Rev. 2.4
Service
13
7. Service
7.1 Service by authorized personnel
7.1.1 Periodic service
The rubber hose on the pump’s pressure side should be replaced at least every five years.
The hoses for detergent and rinse aid should be replaced at least every second year.
7.1.2 Annual maintenance
Annual maintenance should be accomplished in accordance with the following list:
Steps carried out will be marked:
•
che = check
•
cha =change
•
a =adjust
•
m =measure
•
c =cleaning
•
t =tighten
•
f = fix
Check record: middle and basic service (service time; middleserv. 2h, basic serv. 3,5h)
Work order No.___________________________
Service - ID______________________________
Equipment model__________________________
Item
Middle
service
Basic
service
1.
Installation and framework check / adjustment
che / a
che / a
2.
Contactors and other electrical components check / connections tightened
c / t
c / t
3.
Door and hinge check / adjustment
che / a
che / a
4.
Door sprigs check / change
che
cha
5.
Temperatures check / adjustment
che / a
che / a
6.
Solenoid valves clean / fix or change
c
f / cha
7.
Signal lights check / change
che / cha
che / cha
8.
Strainers and filters cleaning
c
c
Summary of Contents for Metos MM-5
Page 23: ...25 3 2003 Rev 2 4 Troubleshooting 18...
Page 25: ...25 3 2003 Rev 2 4 Spare parts 20...
Page 27: ...25 3 2003 Rev 2 4 Spare parts 22 16 1370 1370 14 12 10 12...
Page 29: ...25 3 2003 Rev 2 4 Spare parts 24 250 340 330 300 105 100 290 357 355 350 280 320 130 160 358...
Page 31: ...25 3 2003 Rev 2 4 Spare parts 26 530 660 400 470 480 420...
Page 39: ...25 3 2003 Rev 2 4 Spare parts 34...
Page 43: ...Main circuit diagram 43706 MM5...
Page 44: ...Main circuit diagram 43708 MM5 3 PE 230V 50Hz 3 PE 220V 60Hz...
Page 46: ...Control circuit diagram 43790 MM5 X6 P2...
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......