25.3.2003
Rev. 2.4
Adjustment instructions
11
6. Adjustment instructions
6.1 Setting the rinse aid dosing pump
1.
Rinse aid container
2.
Adjusting screw of the rinse aid dispenser
3.
Boiler
4.
Rinse
•
Set the thinner hose into the rinse aid container.
•
Check that the adjusting screw on the pump is completely opened.
•
Pump so much rinse aid that it reaches the pump (pumping is carried out by press-
ing the adjusting screw in and out). Pump after this 10-15 times.
•
Adjust the quantity of rinse aid by turning the adjusting screw. The basic setting is
about 10 cm measured from the pipe. The amount of rinse aid can be regulated be-
tween 0...4 cm3, which is equivalent to 0...30 cm drawn into the suction tube. The
amount of rinse aid can be reduced by screwing clockwise and increased by screw-
ing counter clockwise.