Firetide - Reliable Connectivity Anywhere
23
February 2009
Appendix C Ethernet Wiring
Custom cables may be constructed following these wiring connections.
Table 4. Circular, Watertight IP66-Rated Pin Descriptions
Connector Pin #
Wire Color
Port Pin #
1
White/Orange
1
2
Orange
2
3
White/Green
3
4
Blue
4
5
White/Blue
5
6
Green
6
7
White/Brown
7
8
Brown
8
Drain Wire
9
Drain Wire
10
Table 5. RJ-45 Connector Pin Descriptions
Pin #
Signal
Description
1
TXD+
TX Data 10 BaseT/100 BaseTX
2
TXD-
TX Data 10 BaseT/100 BaseTX
3
RXD+
RX Data 10 BaseT/100 BaseTX
4
PoE+
Power Input 5 VDC to 48 VDC +
5
PoE+
Power Input 5 VDC to 48 VDC +
6
RXD-
RX Data 10 BaseT/100BaseTX
7
PoE-
Power Input 5 VDC to 48 VDC -
8
PoE-
Power Input 5 VDC to 48 VDC -
Appendix D Reset Procedure
Firetide Access Points may be reset to factory parameters. This is useful when returning a unit from
field service or in recovering a unit you cannot communicate with.
To reset a unit, apply power and wait for the unit to fully boot. This takes 60 to 90 seconds. The
‘status’ LED will glow steady green when the unit is booted.
For indoor units, use a paperclip to press and release the reset button via the small hole on the
back of the unit.
For outdoor units, remove the small cover from the reset switch and activate the reset button.
Wait for the units to reboot before removing power. The status LED will glow green again when it
is safe to remove power.