FireRock ARCHED FRONT Installation, Specification And Operation Manual Download Page 32

32

proper cancellation charges. If Buyer fails to make payment for the Goods when due, Buyer’s account shall be deemed delinquent 

and Buyer shall be liable to FireRock for a service charge of eighteen percent (18%) per annum or the maximum allowed by 

law, whichever is greater, on any unpaid amount; provided that, in addition to the foregoing, FireRock shall also be entitled to 

(w) suspend its performance, (x) cancel any order then outstanding, (y) receive reimbursement for its reasonable and proper 

cancellation charges and (z) proceed to collect, without limitation, any sums due and owing, its reasonable cancellation charges, 

and all damage resulting from Buyer’s default. Buyer shall be liable to FireRock for all costs and expenses of collection, including 

court costs and reasonable attorneys’ fees.

5. SECURITY INTEREST: 

 As collateral security for the payment of the purchase price of the Goods, Buyer hereby grants to 

FireRock a lien on and security interest in and to all of the right, title and interest, to and under the Goods, wherever located, 

and whether now existing or hereafter arising or acquired from time to time, and in all accessions thereto and replacements or 

modifications thereof, as well as all proceeds (including insurance proceeds of the foregoing).  The security interest granted under 

this provision constitutes a purchase money security interest under the Alabama Uniform Commercial Code.

6. CANCELLATIONS, CHANGES AND RETURNS:

  Except as otherwise provided in this Agreement, the order and purchase 

of the Goods under this Agreement are not subject to cancellation, change or return unless agreed to in writing by an authorized 

representative of FireRock. At FireRock’s option, Buyer may be charged for any costs incurred by FireRock prior to or as a result of 

such cancellation, change or return. In the event of any change, FireRock shall be entitled to revise its prices and delivery dates to 

reflect such change. Any Deposit paid to FireRock is non-refundable.

7. DELAY IN OR PREVENTION OF PERFORMANCE: 

 FireRock shall not be liable for any expense, loss or damage resulting 

from delay in delivery or prevention of performance caused by fires, floods, storms, acts of God, strikes, labor disputes, labor 

shortages, lack of or inability to obtain materials, fuels, supplies or equipment, civil unrest, domestic or international acts 

of terrorism, riots, accidents, transportation delays, acts or failures to act of any government or of Buyer, or any other cause 

whatsoever, provided that such cause is beyond the reasonable control of FireRock, and FireRock shall have such additional time 

for performance as may be reasonably necessary under the circumstances and may adjust the price to reflect increases occasioned 

by such delay. Acceptance by Buyer of any of the Goods shall constitute a waiver by Buyer of any claim for damages on account of 

any delay in delivery of the Goods.

8. EXCLUSIVE WARRANTY: 

 Buyer acknowledges that FireRock makes no representation or warranty with respect to the 

Goods, except for the representations and warranties set forth on Exhibit A, which is incorporated into this Agreement by 

reference.

9. LIMITATION OF WARRANTY:

  IF ANY GOOD IS INSTALLED OTHER THAN IN STRICT CONFORMANCE 

WITH THE PUBLISHED INSTALLATION INSTRUCTIONS, THE WARRANTY IS VOID AND THERE SHALL BE NO 

WARRANTY FOR SUCH GOOD.

10. OPERATING WARRANTY SERVICE:

  To obtain warranty service authorization, Buyer must contact the “FireRock 

Technical Service Department” in writing at 1500 1st Avenue North #75, Birmingham, AL 35203, or at such address as may be 

posted at www.firerock.us, within thirty (30) calendar days after Buyer purchases the Goods from FireRock or its authorized 

distributor. Dated proof of original purchase from FireRock or its authorized distributor will be required. FireRock is not 

responsible for Goods received from Buyer without a warranty service authorization. To obtain warranty service authorization, 

Buyer must provide photographic evidence of the claimed defect or have the Goods inspected by an approved FireRock inspector, 

as determined by FireRock in its sole discretion. Buyer agrees to permit inspection of the Goods by an approved FireRock 

inspector. FireRock shall, at its sole discretion, decide the place of performance.

11. WARRANTY DISCLAIMER:

  IF THE GOODS DO NOT OPERATE AS WARRANTED PURSUANT TO THE EXPRESS 

TERMS & CONDITIONS

KEEP THIS INFORMATION FOR YOUR RECORDS

Summary of Contents for ARCHED FRONT

Page 1: ...e consult with local building and zoning authorities regarding the need for proper permitting If the information in this manual including installation instructions is not followed exactly a fire or ex...

Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 3: ...earance to Combustibles Fireplace Installation Foundation Mixing and Applying Mortar Firebox Assembly Arched Lintel Installation Throat and Damper Assembly Smoke Chamber Assembly Chimney Assembly Fire...

Page 4: ...regulations 2 Maintain the stated minimum clearance to combustibles see page 12 and do not violate any specific installation requirement 3 Do not pack air spaces with insulation or other materials 4 F...

Page 5: ...e that building this fireplace is at minimum a two man job REQUIRED MATERIALS EQUIPMENT Concrete for pad foundation Clean water Trowel 5 gallon bucket Level Plastic shims FireRock Adhesive Mortar Fire...

Page 6: ...of the fireplace and chimney This pad or slab should provide for the noncombustible hearth extension substrate needed to support the code required noncombustible hearth extension finish materials Thi...

Page 7: ...to the firebox are allowed with prior written approval and instruction from FireRock The installer indemnifies will defend and hold harmless the manufacturer from all claims and losses and under no c...

Page 8: ...NENTS Components that become broken due to poor handling or shipping should be mortared back together providing the breaks or cracks are clean and original alignment and dimension can be maintained Co...

Page 9: ...level to ensure all components are level by course and plumb as you erect your fireplace and chimney 3 Ensure your base plate is level and at a proper elevation so the finished hearth height including...

Page 10: ...RY INTERTEK COM FOR DETAILED INFORMATION THIS FIREPLACE HAS NOT BEEN TESTED WITH GLASS DOORS TO REDUCE RISK OF FIRE OR INJURY DO NOT INSTALL WITH GLASS DOORS USE SOLID WOOD PROCESSED SOLID FUEL FIRE L...

Page 11: ...22 5 22 5 K WIDTH AT REAR 22 28 34 L OVERALL MINIMUM HEIGHT 75 75 84 375 105 5 OVERALL MAXIMUM HEIGHT 16 0 1 4 16 8 7 8 17 9 before firebrick lining assumes unit is straight front A K F G H C D J L E...

Page 12: ...cle board mill board plywood sub flooring plywood paneling wood flooring and drywall The fireplace must sit on a concrete pad or slab that is designed to bear the total weight of the fireplace and chi...

Page 13: ...firebox and flue system NOTE Use of the FireRock base plate is optional for either of the above foundation types concrete slab or concrete pad FIREPLACE INSTALLATION STEP 1 FOUNDATION DEPTH WIDTH 30 5...

Page 14: ...to ensure maximum strength Use only clean water when mixing FireRock Adhesive Mortar Do not use spirits or anti freeze agents Do not apply if temperatures are below 40 F or will be within a 24 hour p...

Page 15: ...e base plate from the assembly instructions and build the side walls directly on the concrete pad or slab In the event you opt not to use the base plate carefully chalk lines where the base plate woul...

Page 16: ...on is correct Figure 5 6 If building a Straight Front unit build all courses 3 for 30 and 4 for 36 and 42 in this manner making sure each course is level and flush with adjoining components Butter all...

Page 17: ...lock in place just as you have the other components ensuring a level application with an air tight seal Next apply mortar to the front edge of the side blocks and place the Arched Lintel piece in the...

Page 18: ...the square throat front and square throat back These pieces are identical and can be used interchangeably Remember to completely cover each component with mortar 1 2 1 thick where it will lie or butt...

Page 19: ...square throat front Be sure to check for and maintain plumb and level installation of these components Butter all joints to give a smooth appearance and ensure a leak free joint The final component o...

Page 20: ...ar resulting in a 1 16 1 8 joint Butter all joints to give a smooth appearance and ensure a leak free joint The inside face of the chimney should also be buttered to ensure a no leak seal as well as t...

Page 21: ...the floor and work your way back leaving approx gap off the back and side walls Figure 9 1 this space allows for heat expansion and is to be left empty of mortar For the floor only FireRock recommends...

Page 22: ...be utilized as required by the manufacturer Refer to the metal flue manufacturer for assembly instructions FireRock does not manufacture these components and therefore defers to the manufacturer s in...

Page 23: ...e is in use components can become extremely hot and may cause burns or other personal injuries if touched 5 Keep clothing furniture fabrics gasoline liquids with flammable vapors and all other combust...

Page 24: ...below the lintel The maximum recommended fire load is 12 16 pounds of dry firewood at one time about 3 5 cured hardwood logs of approximately 3 6 in diameter Refuel as fire burns down by adding only 1...

Page 25: ...e ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container u...

Page 26: ...LACE PARTS SIDE ELEVATION PLAN ISOMETRIC FRONT ELEVATION BASE PLATE FIREPLACE SIZE DIM A DIM B DIM C 30 38 32 21 1 2 36 44 38 27 1 2 42 50 44 33 1 2 ISOMETRIC PLAN SIDE ELEVATION FRONT ELEVATION FIREB...

Page 27: ...PLAN SIDE ELEVATION FRONT ELEVATION FIREBOX BACK WALL FIREPLACE SIZE DIM A 30 29 7 8 36 35 7 8 42 41 7 8 FRONT ELEVATION SIDE ELEVATION PLAN ISOMETRIC ARCHED LINTEL ARCHED FRONT ONLY FIREPLACE SIZE D...

Page 28: ...28 FIREPLACE PARTS CONTINUED ISOMETRIC FRONT ELEVATION SIDE ELEVATION PLAN SQUARE THROAT FRONT BACK FIREPLACE SIZE DIM A 30 38 36 44 42 50 FRONT ELEVATION ISOMETRIC PLAN SIDE ELEVATION THROAT SIDE...

Page 29: ...TION SIDE ELEVATION PLAN UNIVERSAL SMOKE CHAMBER SIDE FIREPLACE PARTS CONTINUED PLAN FRONT ELEVATION SIDE ELEVATION ISOMETRIC SMOKE CHAMBER FRONT BACK FIREPLACE SIZE ROWS OF BLOCKS NEEDED DIM A 30 1 3...

Page 30: ...30 ISOMETRIC PLAN SIDE ELEVATION CHIMNEY BASE FIREPLACE SIZE DIM A 30 26 36 26 42 32 FIREPLACE PARTS CONTINUED CHIMNEY BLOCK SIDE ELEVATION PLAN ISOMETRIC...

Page 31: ...nsit provided that such claim is received by FireRock within two 2 days of delivery of the Goods to Buyer Any such claims must be accompanied by a delivery receipt signed by carrier s agent at time of...

Page 32: ...y in delivery or prevention of performance caused by fires floods storms acts of God strikes labor disputes labor shortages lack of or inability to obtain materials fuels supplies or equipment civil u...

Page 33: ...SO EXCLUDES FOR ITSELF ITS SUPPLIERS AND THEIR RESPECTIVE SHAREHOLDERS MEMBERS OFFICERS DIRECTORS EMPLOYEES AGENTS AND ITS AND THEIR RESPECTIVE SUCCESSORS AND ASSIGNS ANY LIABILITY WHETHER BASED IN CO...

Page 34: ...the exclusive jurisdiction of such courts in any such Dispute 17 WAIVER No waiver of any provision right or remedy contained in this Agreement is binding on or effective against FireRock unless expre...

Page 35: ...any replaced Fireplace or part for a period of ninety 90 days from shipment or through the end of the original warranty whichever is longer All Fireplaces or parts that are replaced become the proper...

Page 36: ...Version 2 0 10 2018...

Reviews: