19
SMOKE CHAMBER
The smoke chamber components can only be positioned
one way. The fronts and backs are identical above the
damper.
Remember to completely cover each component with
mortar 1/2” - 1” thick where each edge of each component
will lie or butt up against another component.
Align the smoke chamber flush with the back wall of the
fireplace, leaving an approximately 3” “ledge” on top of the
square throat front.
Be sure to check for and maintain plumb and level
installation of these components.
“Butter” all joints to give a smooth appearance and ensure a
leak-free joint.
The final component of the smoke chamber is the chimney
base. Completely cover the tops of all 4 smoke chamber
components with 1/2” - 1” of mortar before placing this final
component and be sure it is level front-to-back and side-to-
side.
“Butter” all joints to ensure a no-leak seal.
FIREPLACE INSTALLATION
STEP 5: SMOKE CHAMBER ASSEMBLY
FIGURE 7.1
SMOKE CHAMBER ASSEMBLY
FIGURE 7.2
COMPLETED FIREBOX AND SMOKE CHAMBER