FireRock ARCHED FRONT Installation, Specification And Operation Manual Download Page 31

31

FIREROCK TERMS & CONDITIONS OF SALE

1. ENTIRE AGREEMENT:

  Fire Rock Products, LLC (“FireRock”) agrees to sell certain Goods (as defined below) to you 

(“Buyer”) on the following terms and conditions of sale (these “Terms and Conditions”), which supersede any additional or 

inconsistent terms of Buyer. As used herein, “Buyer” includes the contractor and the ultimate purchaser of the home or other 

building into which the Goods are installed. These Terms and Conditions and the order or other contract documents to which 

they are attached constitute the entire agreement between FireRock and Buyer with respect to the Goods (collectively, this 

“Agreement”), and the terms and conditions of this Agreement prevail over any of Buyer’s general terms and conditions of 

purchase regardless of whether or when Buyer has submitted its purchase order or such terms.  Fulfillment of Buyer’s order 

does not constitute acceptance of any of Buyer’s terms and conditions and does not serve to modify or amend this Agreement. 

This Agreement may not be modified, amended or waived in any way except in writing signed by an authorized representative of 

FireRock. FireRock makes no representations, except for the representations set forth in these Terms and Conditions, and Buyer 

acknowledges and agrees that Buyer has and will not rely on any other representations.

2. GOODS: 

 FireRock manufactures and sells masonry fireplaces and other products, but these Terms and Conditions are 

limited to the masonry fireplaces purchased by Buyer from FireRock (the “Goods”) and do not apply to other products offered by 

FireRock, which are subject to separate terms and conditions.

3. DELIVERY:

  All shipping dates are approximate. All prices are F.O.B. the location of FireRock’s facility, unless otherwise 

specified by FireRock. Acceptance of shipment by designated shipper, delivery to Buyer’s representative or designee, or mailing of 

an invoice to Buyer, whichever first occurs, shall constitute “Delivery.” Upon payment in full, title shall pass to Buyer. In no event 

shall Buyer be entitled to make any deduction from any payment due hereunder by reason of loss or damage in transit. Upon the 

written request of Buyer, FireRock, at its sole discretion and Buyer’s expense, may agree as a service to Buyer to process Buyer’s 

claim against the carrier for any loss or damage in transit, provided that such claim is received by FireRock within two (2) days 

of delivery of the Goods to Buyer. Any such claims must be accompanied by a delivery receipt, signed by carrier’s agent at time 

of delivery, on which receipt the loss or damage has been noted. In the absence of directions, the Goods will be shipped by the 

method and via the carrier selected by FireRock. Delivery by truck will be made to the nearest points reasonably accessible by 

truck as determined by the driver. Buyer will unload and store, or furnish and pay for any necessary labor to unload and store, the 

Goods, and neither FireRock, the carrier, nor the driver have any obligation to unload or store the Goods. Buyer shall note loss or 

damage on truck shipments upon the delivery ticket returned to FireRock, or such claims shall be waived.

4. TERMS OF PAYMENT:

  Payment terms shall be as described in the applicable order, invoice or other contract documents to 

which these Terms and Conditions are attached; provided, however, if such payment terms are not covered in such documents, 

payment for the Goods are due net cash thirty (30) days from the date of the invoice.  Buyer may be required to pay a percentage 

of the purchase price for the Goods as a deposit for certain custom Goods or new builders or customers whose credit has not been 

approved by FireRock, which is due and payable upon execution of the applicable order (a “Deposit”).  If, at any time or for any 

reason, FireRock shall have cause to question Buyer’s ability to pay, FireRock may demand such assurances of Buyer’s ability to pay 

as FireRock shall deem necessary in its sole discretion, including payment in advance for all shipments. If Buyer fails within ten 

(10) days of FireRock’s demand to provide FireRock with such assurance, FireRock shall be entitled to suspend its performance, 

cancel any order then outstanding, receive reimbursement for its reasonable and proper cancellation charges, and may proceed to 

collect, without limitation, (a) any sums due and owing, (b) its reasonable cancellation charges and (c) all damage resulting from 

Buyer’s default. In the event of an assignment for the benefit of Buyer’s customers or creditors, bankruptcy or insolvency of Buyer, 

or in the event of any proceeding brought against Buyer, voluntarily or involuntarily, under bankruptcy or any insolvency laws, 

FireRock shall be entitled to cancel any order then outstanding at any time and shall receive reimbursement for its reasonable and 

TERMS & CONDITIONS

KEEP THIS INFORMATION FOR YOUR RECORDS

Summary of Contents for ARCHED FRONT

Page 1: ...e consult with local building and zoning authorities regarding the need for proper permitting If the information in this manual including installation instructions is not followed exactly a fire or ex...

Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 3: ...earance to Combustibles Fireplace Installation Foundation Mixing and Applying Mortar Firebox Assembly Arched Lintel Installation Throat and Damper Assembly Smoke Chamber Assembly Chimney Assembly Fire...

Page 4: ...regulations 2 Maintain the stated minimum clearance to combustibles see page 12 and do not violate any specific installation requirement 3 Do not pack air spaces with insulation or other materials 4 F...

Page 5: ...e that building this fireplace is at minimum a two man job REQUIRED MATERIALS EQUIPMENT Concrete for pad foundation Clean water Trowel 5 gallon bucket Level Plastic shims FireRock Adhesive Mortar Fire...

Page 6: ...of the fireplace and chimney This pad or slab should provide for the noncombustible hearth extension substrate needed to support the code required noncombustible hearth extension finish materials Thi...

Page 7: ...to the firebox are allowed with prior written approval and instruction from FireRock The installer indemnifies will defend and hold harmless the manufacturer from all claims and losses and under no c...

Page 8: ...NENTS Components that become broken due to poor handling or shipping should be mortared back together providing the breaks or cracks are clean and original alignment and dimension can be maintained Co...

Page 9: ...level to ensure all components are level by course and plumb as you erect your fireplace and chimney 3 Ensure your base plate is level and at a proper elevation so the finished hearth height including...

Page 10: ...RY INTERTEK COM FOR DETAILED INFORMATION THIS FIREPLACE HAS NOT BEEN TESTED WITH GLASS DOORS TO REDUCE RISK OF FIRE OR INJURY DO NOT INSTALL WITH GLASS DOORS USE SOLID WOOD PROCESSED SOLID FUEL FIRE L...

Page 11: ...22 5 22 5 K WIDTH AT REAR 22 28 34 L OVERALL MINIMUM HEIGHT 75 75 84 375 105 5 OVERALL MAXIMUM HEIGHT 16 0 1 4 16 8 7 8 17 9 before firebrick lining assumes unit is straight front A K F G H C D J L E...

Page 12: ...cle board mill board plywood sub flooring plywood paneling wood flooring and drywall The fireplace must sit on a concrete pad or slab that is designed to bear the total weight of the fireplace and chi...

Page 13: ...firebox and flue system NOTE Use of the FireRock base plate is optional for either of the above foundation types concrete slab or concrete pad FIREPLACE INSTALLATION STEP 1 FOUNDATION DEPTH WIDTH 30 5...

Page 14: ...to ensure maximum strength Use only clean water when mixing FireRock Adhesive Mortar Do not use spirits or anti freeze agents Do not apply if temperatures are below 40 F or will be within a 24 hour p...

Page 15: ...e base plate from the assembly instructions and build the side walls directly on the concrete pad or slab In the event you opt not to use the base plate carefully chalk lines where the base plate woul...

Page 16: ...on is correct Figure 5 6 If building a Straight Front unit build all courses 3 for 30 and 4 for 36 and 42 in this manner making sure each course is level and flush with adjoining components Butter all...

Page 17: ...lock in place just as you have the other components ensuring a level application with an air tight seal Next apply mortar to the front edge of the side blocks and place the Arched Lintel piece in the...

Page 18: ...the square throat front and square throat back These pieces are identical and can be used interchangeably Remember to completely cover each component with mortar 1 2 1 thick where it will lie or butt...

Page 19: ...square throat front Be sure to check for and maintain plumb and level installation of these components Butter all joints to give a smooth appearance and ensure a leak free joint The final component o...

Page 20: ...ar resulting in a 1 16 1 8 joint Butter all joints to give a smooth appearance and ensure a leak free joint The inside face of the chimney should also be buttered to ensure a no leak seal as well as t...

Page 21: ...the floor and work your way back leaving approx gap off the back and side walls Figure 9 1 this space allows for heat expansion and is to be left empty of mortar For the floor only FireRock recommends...

Page 22: ...be utilized as required by the manufacturer Refer to the metal flue manufacturer for assembly instructions FireRock does not manufacture these components and therefore defers to the manufacturer s in...

Page 23: ...e is in use components can become extremely hot and may cause burns or other personal injuries if touched 5 Keep clothing furniture fabrics gasoline liquids with flammable vapors and all other combust...

Page 24: ...below the lintel The maximum recommended fire load is 12 16 pounds of dry firewood at one time about 3 5 cured hardwood logs of approximately 3 6 in diameter Refuel as fire burns down by adding only 1...

Page 25: ...e ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container u...

Page 26: ...LACE PARTS SIDE ELEVATION PLAN ISOMETRIC FRONT ELEVATION BASE PLATE FIREPLACE SIZE DIM A DIM B DIM C 30 38 32 21 1 2 36 44 38 27 1 2 42 50 44 33 1 2 ISOMETRIC PLAN SIDE ELEVATION FRONT ELEVATION FIREB...

Page 27: ...PLAN SIDE ELEVATION FRONT ELEVATION FIREBOX BACK WALL FIREPLACE SIZE DIM A 30 29 7 8 36 35 7 8 42 41 7 8 FRONT ELEVATION SIDE ELEVATION PLAN ISOMETRIC ARCHED LINTEL ARCHED FRONT ONLY FIREPLACE SIZE D...

Page 28: ...28 FIREPLACE PARTS CONTINUED ISOMETRIC FRONT ELEVATION SIDE ELEVATION PLAN SQUARE THROAT FRONT BACK FIREPLACE SIZE DIM A 30 38 36 44 42 50 FRONT ELEVATION ISOMETRIC PLAN SIDE ELEVATION THROAT SIDE...

Page 29: ...TION SIDE ELEVATION PLAN UNIVERSAL SMOKE CHAMBER SIDE FIREPLACE PARTS CONTINUED PLAN FRONT ELEVATION SIDE ELEVATION ISOMETRIC SMOKE CHAMBER FRONT BACK FIREPLACE SIZE ROWS OF BLOCKS NEEDED DIM A 30 1 3...

Page 30: ...30 ISOMETRIC PLAN SIDE ELEVATION CHIMNEY BASE FIREPLACE SIZE DIM A 30 26 36 26 42 32 FIREPLACE PARTS CONTINUED CHIMNEY BLOCK SIDE ELEVATION PLAN ISOMETRIC...

Page 31: ...nsit provided that such claim is received by FireRock within two 2 days of delivery of the Goods to Buyer Any such claims must be accompanied by a delivery receipt signed by carrier s agent at time of...

Page 32: ...y in delivery or prevention of performance caused by fires floods storms acts of God strikes labor disputes labor shortages lack of or inability to obtain materials fuels supplies or equipment civil u...

Page 33: ...SO EXCLUDES FOR ITSELF ITS SUPPLIERS AND THEIR RESPECTIVE SHAREHOLDERS MEMBERS OFFICERS DIRECTORS EMPLOYEES AGENTS AND ITS AND THEIR RESPECTIVE SUCCESSORS AND ASSIGNS ANY LIABILITY WHETHER BASED IN CO...

Page 34: ...the exclusive jurisdiction of such courts in any such Dispute 17 WAIVER No waiver of any provision right or remedy contained in this Agreement is binding on or effective against FireRock unless expre...

Page 35: ...any replaced Fireplace or part for a period of ninety 90 days from shipment or through the end of the original warranty whichever is longer All Fireplaces or parts that are replaced become the proper...

Page 36: ...Version 2 0 10 2018...

Reviews: