4T Latch Mode
This mode of welding is mainly used for long welding runs to reduce operator fatigue. In this mode the operator
can press and release the torch trigger and the output will remain active. To deactivate the power source, the
trigger switch must again be depressed and realized, thus eliminating the need for the operator to hold the
torch trigger.
Note that when operating in GTAW (HF and LIFT TIG modes), the power source will remain activated until the
selected down slope time has elapsed
NOTE
This Up Slope operates in (4T) TIG modes only and is used to set the time for the weld current to ramp up,
after the torch trigger switch has been pressed then released, from Initial Current to High or Weld Current.
Press & hold
Trigger
Weld
Current
High
Current
Down
Slope
Post
Flow
AMPS
TIME
Pre
Flow
Up
Slope
Release
Trigger
Initial
Current
Arc Ignited
Arc Terminated
Press & hold
Trigger
Release
Trigger
Crater
Current
A-11410_AB
Figure 3-4
9. Wave Balance / Arc Force Indicator
This indicator light will illuminate when programming Wave Balance (AC HF TIG mode only) or Arc Force
(STICK mode only).
10. Forward Programming Button
Pressing this button will advance to the next step in the programming sequence.
11. Multifunction Control
The multifunction control knob is used to adjust welding current.
It is also used to adjust parameters when in programming mode.
12. Back Programming Button
Pressing this button will go back to the previous step in the programming sequence.
13. AC frequency Indicator
This indicator light will illuminate when programming AC Frequency (AC HF TIG mode only).
14. Purge Switch
Press the PURGE switch to purge the gas line in LIFT TIG and HF TIG modes. To PURGE the shielding gas
line in LIFT TIG and HF TIG modes press the PURGE switch and release. The indicator will illuminate and
shielding gas will purge for a preset period of 15 seconds. (This cannot be adjusted). To stop shielding gas
from purging within this time press the PURGE switch and release and the purge indicator will extinguish and
shielding gas will cease.
Summary of Contents for TIG 200 AC/DC
Page 6: ...This Page Intentionally Blank...
Page 74: ...FIREPOWER TIG 200 AC DC APPENDIX A 2 Manual 0 5370 Appendix APPENDIX 2 200 AC DC SETUP GUIDE...
Page 75: ...APPENDIX FIREPOWER TIG 200 AC DC Manual 0 5370 A 3 Appendix A 12718...
Page 76: ...FIREPOWER TIG 200 AC DC APPENDIX A 4 Manual 0 5370 Appendix This Page Blank Intentionally...
Page 77: ...This Page Intentionally Blank...