SAFETY AND INSTALLATION
FIREPOWER 160 S
Manual 0-5371
3-5
Safety and Installation
3.03 Environment
These units are designed for use in environments with increased hazard of electric shock. Examples of environments
with increased hazard of electric shock are:
A. In locations in which freedom of movement is restricted, so that the operator is forced to perform the work in
a cramped (kneeling, sitting or lying) position with physical contact with conductive parts.
B. In locations which are fully or partially limited by conductive elements, and in which there is a high risk of
unavoidable or accidental contact by the operator.
C. In wet or damp hot locations where humidity or perspiration considerably reduces the skin resistance of the
human body and the insulation properties of accessories.
Environments with increased hazard of electric shock do not include places where electrically conductive parts in
the near vicinity of the operator, which can cause increased hazard, have been insulated.
3.04 Location
Be sure to locate the welder according to the following guidelines:
• In areas, free from moisture and dust.
• Ambient temperature between 14°F (-10°C) to 104° F (40° C).
• In areas, free from oil, steam and corrosive gases.
• In areas, not subjected to abnormal vibration or shock.
• In areas, not exposed to direct sunlight or rain.
• Place at a distance of 12” (300mm) or more from walls or similar that could restrict natural air flow for
cooling
!
WARNING
Firepower advises that this equipment be electrically connected by a qualified electrician.
Summary of Contents for TIG 160S
Page 6: ...This Page Intentionally Blank ...
Page 18: ...FIREPOWER 160 S INTRODUCTION Introduction 2 2 Manual 0 5371 Notes ...
Page 30: ...FIREPOWER 160 S SAFETY AND INSTALLATION Safety and Installation 3 12 Manual 0 5371 Notes ...
Page 40: ...FIREPOWER 160 S THEORY OF OPERATION Theory of Operation 5 2 Manual 0 5371 Notes ...
Page 54: ...FIREPOWER 160 S TROUBLESHOOTING Troubleshooting 6 14 Manual 0 5371 Notes ...
Page 59: ...DISASSEMBLY PROCEDURE FIREPOWER 160 S Manual 0 5371 7 5 Disassembly Procedure 4 Art A 09866 ...
Page 66: ...FIREPOWER 160 S DISASSEMBLY PROCEDURE Disassembly Procedur 7 12 Manual 0 5371 Notes ...
Page 69: ...ASSEMBLY PROCEDURES FIREPOWER 160 S Manual 0 5371 8 3 Assembly Procedures 8 Art A 09883 ...
Page 74: ...FIREPOWER 160 S ASSEMBLY PROCEDURES Assembly Procedures 8 8 Manual 0 5371 Notes ...
Page 78: ...FIREPOWER 160 S REPLACEMENT PARTS Replacement Parts 9 4 Manual 0 5371 Notes ...
Page 80: ...FIREPOWER 160 S ACCESSORIES Accessories 10 2 Manual 0 5371 Notes ...
Page 83: ......