AnF Enclosures
REV. 8-29-18 Page 5
STEP 5
After the entire AnF is assembled, install the Vent-Kit-6x12. These vents are designed to be used
with the AnF Series as well as universal vents for many other types of fi re pit enclosures. Look at the
contents provided to ensure you have received everything correctly.
(2) Vents
(12) Phillips Black
Pan Head Screw
(12) Stainless Steel
Nut
(2) Stainless Steel
Flat Washer
Install the vents on opposite sides of the enclosure to ensure cross fl ow ventilation. Cross fl ow
ventilation is necessary to provide free fl owing air to assist in keeping the enclosure dry and cool
during operation of a fi re pit.
Cut an rectangular opening 9.750”w x 3.750”h
into on opposite sides of the enclosure. Center
the vent over the cut out area ensuring the vent
slots are clear of any obstruction. Mark the holes
with a pencil or marker. Drill six 1⁄4” pilot holes,
position the vent centered over the opening,
insert a screw into the vent and enclosure at
the same time and secure with washer and nut
on the inside. Repeat the process until all six
screws are securing each vent into place on
both sides of the AnF enclosure (See Fig. 11).
9.750”
3.750”
CUT OUT DETAIL
Fig. 11
Vent Cut Out Dimensions
NOTE:
Before cutting the rectangular opening
for your vents, be sure that you are not hitting
one of the metal studs inside the AnF. The vents
must be directly across from each other.