FireBird Enviromax Popular C26 Technical Manual Download Page 35

terMs & CondItIons oF warranty

Firebird products are designed and manufactured to give 
many years of trouble free service.

The terms laid down in the warranty must be adhered to.

u

  Firebird  provides  a  comprehensive,  conditional           

warranty of 5 years on the boiler shell and 2 years 
on     all other parts from date of installation, provided   
installation has occurred within 12 months from date 
of purchase.

u

  The 5 year boiler shell warranty consists of parts and 

labour for the first 3 years and parts only for years 4 and 
5.

u

 The warranty will only apply if the boiler is 

commissioned by an OFTeC registered or competent, 
qualified engineer and is serviced annually thereafter.

u

  Please ensure that the commissioning card is fully 

completed by a competent, qualified engineer and is 
returned to Central Heating New Zealand within 28 
days of complete installation and commissioning. 

u

  Correct commissioning will ensure that your boiler is 

set to operate at its maximum fuel efficiency.

u

  Consumable components, the nozzles and the oil hose 

are excluded.

terMs & CondItIons oF warranty 

1.  Warranty implies that the product shall be free from 

defective parts or workmanship for a period of warranty 
cover, which begins from the date ofinstallation.

2.  all claims under the warranty programme must be 

within the time limits stated on the left.

3.  Installation and commissioning of the product must 

be  in  accordance  with  (a)  instruction/technical            
manuals  (b)  all  relevant  standards  and  codes  of           
practice.

4.  a competent, qualified engineer, using the correct 

installation  and  test  equipment  must  carry  out        
installation and commissioning.

5.  This warranty does not cover special, incidental or 

consequential damages, injury to persons or property, 
or any other consequential loss.

6.  Servicing of the boilers is to be carried out annually to 

maintain the manufacturer’s warranty.

7.  Firebird accepts no liability in respect of any defect 

arising from incorrect installation, negligence, 
fair  wear  and  tear,  misuse,  alteration  or  repair  by                
unqualified persons.

8.  Firebird will not accept any liability in respect of any 

defect occurring to the product due to limescale 
build-up and or low return water temperature.

9.  The warranty programme extends to reasonable 

labour costs eXCePT in the case of a 5 year warranty 
period whereby any valid claim made after 3 years will 
not include labour costs.

10.  Firebird’s prior authorisation must be obtained before 

examination or repair of the product takes place.

11.  Firebird  will  examine  all  claims  made  under  the            

warranty programme and for any claims that are 
deemed invalid, the costs incurred will be borne by 
the owner.

12. The warranty programme only applies where the 

product  was  used  for  normal  domestic  heating               
purposes.

13. any defective part removed under any or all of the 

warranty programmes MUST be returned to Central 
Heating New Zealand.

14. Burner controls and flue kits (supplied by Firebird), 

will be free from defective parts or workmanship for a 
period of 2 years form the date of installation (with the 
exception of burner nozzles, which must be replaced 
at the recommended service intervals).

STATUTORY RIGHTS OF THE OWNER ARE NOT

AFFECTED BY THIS WARRANTY

8

35

Summary of Contents for Enviromax Popular C26

Page 1: ...This manual must remain with the householder once installation is complete HEATING SOLUTIONS ENVIRONMENT INNOVATION TECHNOLOGY Technical Manual Condensing BoileR...

Page 2: ...mbustion Air Requirements 14 3 5 Liquid Fuel Supply 15 4 SYSTEM Condensing BOILER 4 1 End User Information 16 4 2 Installer Guidelines 19 4 3 Technical Details 21 5 SYSTEMPAC Condensing BOILER 5 1 End...

Page 3: ...ace the critical advantage provided by training and years of experience Firebird domestic condensing boilers are highly efficient and are all ErP A rated Energy related Products They use less fuel and...

Page 4: ...be sought following eye contact or prolonged reddening of the skin The small quantities of adhesives and sealants used in the product are cured They present no known hazards when used in the manner fo...

Page 5: ...ook Four Oil fired appliance system installation requirements Copies of British Standards may be purchased direct from BSI Customer Services 389 Chiswick High Rd London W4 4AL Tel 44 0 345 0869001 Int...

Page 6: ...in an unheated garage should not exceed 3 meters and Should be lagged with water proof insulation to prevent freezing Boiler Sealed Condensate Drain Discharge Pipe 75mm Soak Away Lime Stone Chippings...

Page 7: ...STANDARDS REGULATIONS Condensate Disposal Condensate Trap Fitting 1 Push washer into trap socket and screw trap onto boiler socket 2 Push flexible pipe onto trap socket 3 Final assembly Washer S S tr...

Page 8: ...3 3 1 STANDARDS REGULATIONS Condensate Disposal System No 2 Condensate Pump Indent Order Condensate PUMP kit is available as an optional extra 8...

Page 9: ...B C D K F F L N O P H J Boundary Boundary F Q Q Q Q Q Q Q R Pressure Jet Location Appliance Burner Type Condensing UK A Directly below an opening airbrick opening window etc 1000mm B Horizontally to a...

Page 10: ...or low level flue and low level balanced flue discharge when tested to BS EN 303 1 5 Terminating positions must be at least 1 8m distant from a fuel storage tank unless a wall with at least 30 minutes...

Page 11: ...disperse vapours 3 The effect of the moisture generated must be considered in relation to the possible corrosion of metal parts it might reach and to the possible formation of ice on pathways in freez...

Page 12: ...sing birdguard System 35 clamp plate System 35 clamp plate System 35 flexible liner suitable for condensing applications System 35 adaptor 500mm Adjustable length Boiler adaptor Condensing boiler Cond...

Page 13: ...ax length 6m Overall length must take into account bends where 45 bend 0 5m length and 90 bend 1m length INSTALLATION INSTRUCTIONS SUPPLIED WITH ALL FLUE KITS Elbows 45 90 Adjustable extensions 305 42...

Page 14: ...photocell has stopped a burner 1 Ensure that the gasket door is sealed correctly to the boiler 2 Ensure that the burner collar is in place If you see that the burner collar and surrounding area is ge...

Page 15: ...allow household waste or hot ashes container in vicinity of oil storage tank or boiler flue outlet 15 Flexible Oil Pipe s Two flexible burner Diesel hoses are supplied with the boiler which must be w...

Page 16: ...the event of the control thermostat failing and keeps the boiler safe The safety high limit thermostat will shut the boiler off and will require the limit button to be pushed to restart the boiler It...

Page 17: ...ING The boiler thermostat control and safety system is not designed and must not be relied on to protect plastic pipe from overheating Additional measures must be incorporated into the system pipework...

Page 18: ...e measured in bar equals static head of system measured in bar plus 0 3 Sealed Heating Circuit The system must comply with BS 7074 Part 1 and BS 5449 Part 1 with a maximum water temperature of 80 C A...

Page 19: ...n Mains cold water is supplied through the boiler drain fill valve Heating Circuit This is the heating system including the boiler which is filled from the mains supply via a flex filling loop to a pr...

Page 20: ...to operate the post purge function on the burner when applicable If a permanent live supply is not provided the burner will not operate Mains Burner Limit Lockout WIRING Electrical Supply The boiler a...

Page 21: ...Condensing output range Weight kg Dimensions mm H W D A B C E F G I J K L C26 System Condensing 26kW 148 856 555 618 760 231 165 210 580 648 341 78 62 93 C35 System Condensing 35kW 151 856 555 618 760...

Page 22: ...pocket ACC003PKT ACC003PKT 8 1 Condensate trap ACC000TRP ACC000TRP 9 1 Condensate hose ACC000FLX ACC000FLX 10 1 Heat deflector ACC000HTD ACC000HTD 11 1 Air hose ACC000SSH ACC000SSH 12 1 Control panel...

Page 23: ...mm dia plastic pipe 22 mm dia plastic pipe Circulating Pump 25 60 25 60 Integral Expansion Vessel Normal Capacity 12 litres 12 litres Expansion Vessel Pre charge Pressure 1 bar 1 bar Low Pressure Wate...

Page 24: ...the event of the control thermostat failing and keeps the boiler safe The safety high limit thermostat will shut the boiler off and will require the limit button to be pushed to restart the boiler It...

Page 25: ...IPING The boiler thermostat control and safety system is not designed and must not be relied on to protect plastic pipe from overheating Additional measures must be incorporated into the system pipewo...

Page 26: ...ure measured in bar equals static head of system measured in bar plus 0 3 Sealed Heating Circuit The system must comply with BS 7074 Part 1 and BS 5449 Part 1 with a maximum water temperature of 80 C...

Page 27: ...on Mains cold water is supplied through the boiler drain fill valve Heating Circuit This is the heating system including the boiler which is filled from the mains supply via a flex filling loop to a p...

Page 28: ...otection It is also required to operate the post purge function on the burner when applicable If a permanent live supply is not provided the burner will not operate WIRING Electrical Supply The boiler...

Page 29: ...J A L E F G K B Model Systempac Condensing output range Weight kg Dimensions mm H W D A B E F G I J K L C26 Systempac Condensing 26kW 160 945 597 651 795 242 92 633 44 271 133 121 236 C35 Systempac C...

Page 30: ...at pocket ACC003PKT ACC003PKT 8 1 Condensate trap ACC000TRP ACC000TRP 9 1 Condensate hose ACC000FLX ACC000FLX 10 1 Heat deflector ACC000HTD ACC000HTD 11 1 Pressure vessel ACC012PVL ACC012PVL 12 1 Insp...

Page 31: ...es 24 litres Flue Indoor Boilers Balanced Flue Assembly 125 5 mm dia 125 5 mm dia Max Low Level Flue Length 1 5m 1 5m Max High Level Balanced Flue Length 6m 6m Heating System Sealed Fit in accordance...

Page 32: ...done with the boiler in the condition it is going to be operating at that is if a balanced flue is installed the air hose is fixed on the burner In the case of a Slimline Heatpac ensure that the door...

Page 33: ...lear of all foreign matter Refill the system and again vent at all points as described Examine the complete system for water leaks having pressurised it to 1 2 5 bar Correct any leaks then check opera...

Page 34: ...leaks Draw off any accumulated water and sludge from the tank by opening the drain valve Turn off the diesel supply and remove the filter bowl then wash the element clean with diesel Fit a new element...

Page 35: ...nt qualified engineer using the correct installation and test equipment must carry out installation and commissioning 5 This warranty does not cover special incidental or consequential damages injury...

Page 36: ...Valve Location Condensate Trap where fitted Condensate Trap Piped to Drain Condensate Trap Primed Float and Condensate Trap in Place Check Flue Seals Deflector Plate and Baffles Graphite Door Seal and...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...e the specification of our products at any time and be without obligation to make similar changes in products previously produced MLOBNZEB000 For further information on Firebird products please contac...

Reviews: