910.100.276GB  REV00                                                                                                          1 di 28 

 

INSTRUCTION MANUAL 

 

Summary of Contents for Tp 72

Page 1: ...910 100 276GB REV00 1 di 28 INSTRUCTION MANUAL ...

Page 2: ...910 100 276GB REV00 2 di 28 ...

Page 3: ...910 100 276GB REV00 3 di 28 WARNING ...

Page 4: ...910 100 276GB REV00 4 di 28 ...

Page 5: ...910 100 276GB REV00 5 di 28 ...

Page 6: ...12 MAXIMUM RATED INPUT CURRENT 13 MAXIMUM EFFECTIVE INPUT CURRENT 14 APPLICABLE STANDARDS 15 RANGE OF WELDING VOLTAGE CURRENT 16 DUTY CYCLE 17 RATED WELDING CURRENT 18 CONVENTIONAL LOAD VOLTAGE TECHNICAL DATA Weigh 14Kg Dimensions 170x450x320 Static characteristic Drooping Power supply protection Slow Action 25A Fuses Int 3ph 25A C or K Type Input voltage 400V 10 Thermal Protection Bimetallic ther...

Page 7: ...gible at all times Fimer S p A reserves the right to modify this manual at any time without notice All rights of translation and total o partial reproduction by any means whatsoever including scanner photocopy film and microfilm are reserved and reproduction is prohibited without the express written consent of Fimer S p A WARNING 3 SAFETY RULES 8 PRECAUTIONS 8 PRESSURE REGULATOR 9 OVERVIEW 9 HOW T...

Page 8: ...perator s body and clothing dry DO NOT stand in sit on lie on the workpiece when the generator is running Avoid working in damp surroundings or on wet ground Check that the output cables and the power cord do not show areas where the copper is even partially open in which case replace it immediately Disconnect power supply while working on the torch on the generator or the cables Never place the t...

Page 9: ...sed of A Current generator B Cutting torch C ground cable with clamp The essential parts of the TP generators are Electronic control card Power Electronic control card The use of inverter systems allows for a compact generator to cut on restricted areas and achieve high quality The high frequency used by the inverter 35 kHz allows you to control the arc in the most suitable for the cutting Changes...

Page 10: ... flow of air through the air intake grills avoid cover the generator with rags paper nylon etc 2 Make sure that the air sucked in the unit is at temperatures below 40oC and the working environment is not particularly polluted or is not in the presence of a moist air with the presence of dust mixed with acids or salts b air with a strong presence of ferrous metal powders 3 Verify that the value of ...

Page 11: ...f the unit to the network verify that the supply voltage is 400 VAC 10 ATTENTION if the voltage exceeds 440Vac the generator stops Voltages over 460 VAC can seriously damage the generator PROTECTIONS The generators have different internal protection Protection against maximum voltage of the mains Protection against minimum voltage of the mains Thermal Protection Inverter overcurrent protection Ele...

Page 12: ...910 100 276GB REV00 12 di 28 OPERATOR PANEL 7 9 1 12 3 2 4 5 6 8 10 11 13 14 15 ...

Page 13: ... turns ON or OFF the converter 15 Connector for remote control of the cutting current REMOTE CONTROL CONNECTOR The functions corresponding to the connector pins are PIN 1 6 normally open contact 120 VAC 1 A max closes when the arc is transferred to the piece PIN 3 output current adjustment The generator is prepared for a 0 10 VDC signal to adjust the output current where input signal 0VDC output c...

Page 14: ... hole ruined or very extended compared to new Too thick piece Heart clamp not in good electrical contact with the workpiece 2 Cutting arc goes off The causes of this problem can be Feed rate too low Cutting current too high in relation to the thickness of the workpiece adjust to the thickness PRACTICAL ADVICE If the air contains moisture and or oil is good to use a dryer filter to prevent excessiv...

Page 15: ...void damaging the torch always use genuine parts FIMER THE OPERATIONS REQUIRING ACCESS INSIDE THE MACHINE MUST BE EXECUTED AFTER DISCONNECT THE POWER PLUG FROM THE OUTLET TECHNICAL DATA The inverter is a special oscillating circuit that supplied by an input continuous voltage provides an output AC voltage having the frequency required Increasing the frequency achieves multiple benefits Use of powe...

Page 16: ...910 100 276GB REV00 16 di 28 SCHEMATIC DIAGRAM ...

Page 17: ... Solenoid 9 Filter Card 10 Resistor 15 Ohm 50 W 11 Fan 12 Ground Connector 13 LP Solenoid 13 1 Reduction for LP 14 High frequency card 15 Resistor 33 Ohm 100 W 16 Toroidal transformer 17 Power Supply Card 18 Inverter Card 19 Regulator Card 20 Mains Switch 21 HF transformer 22 Power transformer 23 Cable holder ...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: