5. Safety instructions

This system may cause bodily harm or damage to property if 
you do not use it properly and in accordance with all safety 
guidelines,  or  if  you  attempt  to  use  it  for  any  purpose  other 
than that for which it was designed. This system must never be 
operated by children or anyone under the age of 16, or by anyone 
who  has  a  physical,  mental  or  sensory  impairment  or  lack  of 
experience and knowledge, unless they are under supervision 
and have been instructed on the safe usage of the system and 
informed of the dangers associated with it. Children must be 
made aware that this system is not a toy. Cleaning and mainte-
nance must be performed by an adult user. This must never be 
performed by a child, even if they are under supervision.

5.1  danger of electrical shock in contact with water

If  your  system  has  not  been  connected  properly  and  in 
accordance  with  the  safety  guidelines,  and  a  live  electrical 
current comes into contact with water, this can result in electrical 
shock, causing serious injury and even death. Always switch off 
the current on any water-bearing equipment before you come 
into contact with the water.

5.2  Pacemakers

The cover has a magnetic switch. The magnetic field may interfere 
with pacemakers.

5.3  Guidelines for electrical installations

The  electrical  installation  must  be  carried  out  in  accordance 
with  all  national  legislation  and  may  only  be  performed  by  a 
nationally certified electrician. A person is considered an electrician 
if  they  have  the  appropriate  training,  knowledge,  experience 
and certification, and are capable of assessing and conducting 
the  necessary  work.  The  job  of  an  electrical  specialist  also 
includes recognising any possible hazards and complying with 
all applicable regional and national standards, regulations and 
provisions of law.

• 

For your own safety, always consult a professional electrician 
in case of any problems.

• 

This system can only be connected to a power supply that 
matches its electrical specifications. All specifications for 
this system can be found in this user manual.

• 

The system must be protected by a residual current device 
with a fixed residual current of max. 30 mA.

• 

Use  only  extension  cables  and  power  dividers  that  are 
splash-proof and whose cable diameters are the same as 
the ones supplied with the system.

• 

Do  not  allow  the  plug  connections  to  come  into  contact 
with water or moisture.

• 

Connect the system only to a power outlet that has been 
installed  according  to  industry  standards  and  does  not 
contain a dimmer.

5.4  Safe use

• 

Never use this system in connection with faulty electrical 
cables or a defective housing.

• 

Never pull on the cables to adjust the placement of the 
system.  Ensure  that  the  electrical  cables  are  not  pulled 
tightly.

• 

Lay the cables through a secure duct to avoid damage and 
make sure no one can trip or fall over them.

• 

Only  open  the  housing  of  the  motor  or  other  electrical 
components if this is necessary as instructed by the user 
manual.

• 

Only perform maintenance and other tasks on the system 
as described in this user manual.

• 

In  case  of  any  problems  that  you  are  unable  to  resolve, 
please contact Filtreco.

• 

Only use original spare parts in combination with this system.

• 

Do  not  attempt  to  modify  the  technical  features  or 
specifications of this system in any way.

• 

The connector cables cannot be replaced. In case of a broken 
cable, the entire system or affected part must be replaced 
entirely.

• 

When using in the open air, a roof must be placed above 
the control box and a rain-proof cover must be placed above 
the motor.

• 

Over-voltage  in  the  mains  can  cause  the  system  to 
malfunction. 

• 

Do not inhale the spray mist from the sprayer system. The 
spray mist may contain harmful bacteria.

• 

If the cover is lifted, the flush system stops working. Once 
the  flush  cycle  has  completed,  allow  some  time  before 
opening the cover.

Summary of Contents for 100300

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100300 User manual Drum 35 gravity EN Order number...

Page 2: ......

Page 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Drum 35 gravity By purchasing this F...

Page 4: ......

Page 5: ...tions 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting wa...

Page 6: ...ass the drum and flow past it without being filtered This enables you to still use the biological filtration segment The basin is fitted with a removable waste drain The inclined surface accelerates t...

Page 7: ...For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications...

Page 8: ...diameter Make sure that the duct is positioned at an adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and als...

Page 9: ...g for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket...

Page 10: ...d or stop the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work...

Page 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must increase the inflow capacity to the filter or r...

Page 12: ...ge Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After yo...

Page 13: ...al between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of t...

Page 14: ...14 Drum 35 gravity 16 Technical diagram...

Page 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P...

Page 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand...

Reviews: