7.  First use

Before using the drum filter for the first time, it is advisable to 
thoroughly clean the pond manually and flush the pipelines if 
possible. The reason for this is to prevent the newly started filter 
from immediately experiencing an interval breakdown.

Note! Electrical shock hazard.

 

• 

Always switch off the current to the system before coming 
into contact with the pond water.

• 

Secure the system to prevent it from unintentionally being 
switched on.

• 

Never connect the system to a power supply that is fitted 
with a dimmer.

• 

Do not use the system in combination with a switch that 
has a timer function.

• 

Only  switch  on  the  control  box  if  the  submersible  pump 
is below the water level and the electrodes are below the 
surface.

7.1  Sequence for first use

• 

Remove the cover from the filter.

• 

Check all the water inlet and outlet connections.

• 

Check the line from the pump to the spray tube to ensure 
it is hand-tight.

• 

Open the valves on the outflow side.

• 

Open one valve in the in-flow line.

• 

Fill  the  pond  and  filter  until  the  maximum  water  level  is 
reached.

• 

Adjust the placement in case the water level is not reached.

• 

Check all the water inlet and outlet connections again.

• 

Plug the connectors into the corresponding power sockets:

The plug for the spray pump goes into the power socket labelled 
"spray pump". 
The plug for the drum motor goes into the power socket labelled 
"drum motor".
The  plug  for  the  water  pump(s)  goes  into  the  power  socket 
labelled "pond pump".
Any  additional  components  connect  into  the  power  socket 
labelled "spare".

Please make sure that the power sockets can support a total 
output of 2500 W from "pond pump" and "spare" combined! 

7.2  Adjusting water level meter

The water level meter consists of 3 stainless steel electrodes:

• 

The low-level electrode: the long coated electrode

• 

The flush electrode: the short coated electrode

• 

The common electrode: the long uncoated electrode

The flush-cycle electrode is set to the lowest level by default. 
This means that the flush cycle is initiated when the water level 
drops by approximately 90 mm before the low level is reached.

If you would like for the flush cycle to take place sooner, you 
can  unscrew  the  cable  gland  and  place  the  electrode  higher. 
Afterwards, tighten the cable gland again.

Note! The two long electrodes do not have an adjusting function.

7.3  Flush cycle

If the pond's water quality is such that the flush cycle lasts less 
than 3 minutes, then the flow into the drainage duct must be 
reduced to ensure that the cycle lasts for more than 3 minutes. 
After  the  contamination  in  the  pond  has  decreased,  the 
throttling  in  the  drainage  duct  can  be  gradually  reduced  as 
long as you allow for the flush cycle time mentioned above.

Summary of Contents for 100300

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100300 User manual Drum 35 gravity EN Order number...

Page 2: ......

Page 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Drum 35 gravity By purchasing this F...

Page 4: ......

Page 5: ...tions 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting wa...

Page 6: ...ass the drum and flow past it without being filtered This enables you to still use the biological filtration segment The basin is fitted with a removable waste drain The inclined surface accelerates t...

Page 7: ...For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications...

Page 8: ...diameter Make sure that the duct is positioned at an adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and als...

Page 9: ...g for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket...

Page 10: ...d or stop the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work...

Page 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must increase the inflow capacity to the filter or r...

Page 12: ...ge Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After yo...

Page 13: ...al between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of t...

Page 14: ...14 Drum 35 gravity 16 Technical diagram...

Page 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P...

Page 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand...

Reviews: