Filtreco 100300 User Manual Download Page 12

12

drum 35 (gravity)

9 LEds for the selected time interval:

Depending on how dirty the water is, you can choose between 
5 different flush times. 

The normal flush time can be used for average water contami-
nation.  If  the  pond  is  very  clean  and  hardly  contains  any 
contaminants, such as in the winter time, you can switch to the 
"eco" or "smart" setting. This reduces your water consumption. If 
the water is heavily contaminated and you would like to flush 
the  screen  more  frequently,  you  can  choose  the  "super"  or 
"turbo" setting.

You  can  change  the  selected  flush  times  in  Manual  mode  by 
pressing "Change Flush Time". 

The sprayer does not begin spraying until 1.5 seconds after the 
motor starts. This ensures that only the soiled portion of the 
screen is sprayed.

The Eco setting has a spray time of 5.5 seconds (quarter turn).
The Smart setting has a spray time of 8 seconds (half turn).
The Normal setting has a spray time of 11 seconds (1 turn).
The Super setting has a spray time of 22 seconds (2 turns).
The Turbo setting has a spray time of 33 seconds (3 turns).

Make sure that there is an interval of at least 3 minutes between 
flush cycles, otherwise the drum will experience an interval error.

Confirm your choice by pressing "Change Mode". Your choice 
is now saved. In manual mode, you can change this again if you 
wish.

10 Safety Switch:

If the 'Safety Doorswitch E' is switched on, the system is supplied 
with electrical current. After you use 'Safety Doorswitch E', the 
system will always start in Manual mode. If you want to open 
the control box, you must switch off 'Safety Doorswitch E' or 
else  the  door  cannot  be  opened.  This  is  an  additional  safety 
feature.

10.  Cleaning and maintenance

Note! Electrical shock hazard! This can result is severe injury 
or death.

When performing cleaning and maintenance, always take the 
following measures:

• 

Always  switch  off  the  power  supply  and  secure  it  from 
being accidentally switched back on before you come into 
contact with the water or perform any maintenance work 
on the system.

• 

General cleaning - 1x each month:

 

-  Switch off the "Main switch" and unplug the system from  

 

  the mains power supply.

 

-  Remove  any  coarse  waste  (such  as  algae)  on  the 

 

  inside of the drain.

 

-  Clean the brushes inside the drum.

 

-  Clean the inside of the drum.

 

-  Clean the door security blocks.

 

-  Clean the water level meter electrodes.

• 

Cleaning the sprayer heads - 2x per month:

 

-  Remove  the  sprayer  head  by  turning  it  to  the  left  

 

  to unscrew it from the quick-release fastener.

 

-  Remove the gasket from the holder.

 

-  Remove the right-angle sprayer from the connector.

 

-  Clean it.

 

-  Install the gasket and sprayer back into the holder.

 

-  Turn the holder onto the clamp bracket. 

Summary of Contents for 100300

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100300 User manual Drum 35 gravity EN Order number...

Page 2: ......

Page 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Drum 35 gravity By purchasing this F...

Page 4: ......

Page 5: ...tions 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting wa...

Page 6: ...ass the drum and flow past it without being filtered This enables you to still use the biological filtration segment The basin is fitted with a removable waste drain The inclined surface accelerates t...

Page 7: ...For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications...

Page 8: ...diameter Make sure that the duct is positioned at an adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and als...

Page 9: ...g for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket...

Page 10: ...d or stop the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work...

Page 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must increase the inflow capacity to the filter or r...

Page 12: ...ge Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After yo...

Page 13: ...al between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of t...

Page 14: ...14 Drum 35 gravity 16 Technical diagram...

Page 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P...

Page 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand...

Reviews: