6 Error LEd:

This LED glows red whenever an error or outage occurs. This 
may indicate any of the following errors:

System Error:

Error  in  the  control  box  (relay,  electrodes,  automation, 
motherboard).

 

-  The water pumps are switched off. 

 

-  No flush cycle is possible.

• 

The Main Switch is switched off

• 

Pull all the plugs out of the box

• 

Unplug the system's power supply cable

• 

Switch the F1 automat off and then on again

• 

Close the box and reconnect it to power

• 

Switch the Main Switch on again

• 

If the error continues, contact Filtreco

Level Error:

The water level in the filter has become too low. More water is 
being pumped out of the filter than is flowing into it.

 

-  The water pumps are switched off. 

 

-  No flush cycle is possible.

• 

Remove the cover and look for what's causing the problem.

• 

Check the inlet and outlet lines.

• 

If the outer end of the flush level is under water again:

 

-  place the cover on the filter

 

-  press "Reset Error" 

 

-  The mode will then switch to Manual

• 

Press "Start" to initiate the manual flush cycle.

 

-  The "Flush" LED turns green

 

-  Check to make sure the spray pump and motor are working

 

-  If  the  motor  is  not  working,  check  whether  its  plug  is  

 

  connected

 

-  If the spray pump is not working, check whether its plug 

 

  is connected

 

-  When  the  flush  cycle  is  complete,  the  "Flush"  LED 

 

  switches off again.

 

-  Remove  the  cover  and  check  whether  the  water  level  

 

  has reached the required operating level again

 

-  Repeat the steps above if necessary

 

-  If this continues to happen, you must increase the inflow  

 

  capacity to the filter or reduce the pump capacity from  

 

  the filter.

Door Error:

The cover (contact) is not closed. The cover is not installed or 
is not closed properly.

 

-  The water pumps are switched off. 

 

-  No flush cycle is possible.

• 

Check whether the cover is closed properly

• 

Press "Reset Error" to return to the manual cycle

• 

The  "Door"  LED  switches  off  and  the  "Manual"  LED 
switches on

• 

Press "Change Mode" to return to automatic mode.

If the error continues, check whether the magnet is still in place 
under the holder for the cover. If so, then perform the following 
steps:

• 

Switch off the "Main Switch" 

• 

Disconnect the power plug from the mains

• 

Open the box

• 

Check  whether  the  DR+  and  DR-  cables  are  properly 
connected

Interval Error:

This occurs when 50 flush cycles have occurred in a row with 
a pause of less than 3 minutes between each cycle. This may 
occur when the water is heavily contaminated.

 

-  The water pumps are switched off.

• 

Set the flush electrode to the lowest level. Now, a flush cycle 
will be initiated later.

• 

Check the inflow lines to see whether they are clogged.

• 

Check the sprayer heads and clean them if needed.

If this does not help, reduce the outgoing flow until the most 
heavy contamination is eliminated.

7 Auto mode LEd:

The LED glows then the system is in automatic mode.

8 manual mode LEd: 

The LED glows when the system is in manual mode.

Summary of Contents for 100300

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100300 User manual Drum 35 gravity EN Order number...

Page 2: ......

Page 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Drum 35 gravity By purchasing this F...

Page 4: ......

Page 5: ...tions 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting wa...

Page 6: ...ass the drum and flow past it without being filtered This enables you to still use the biological filtration segment The basin is fitted with a removable waste drain The inclined surface accelerates t...

Page 7: ...For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications...

Page 8: ...diameter Make sure that the duct is positioned at an adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and als...

Page 9: ...g for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket...

Page 10: ...d or stop the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work...

Page 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must increase the inflow capacity to the filter or r...

Page 12: ...ge Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After yo...

Page 13: ...al between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of t...

Page 14: ...14 Drum 35 gravity 16 Technical diagram...

Page 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P...

Page 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand...

Reviews: