11
www.filtreco.nl
6 Error LEd:
This LED glows red whenever an error or outage occurs. This
may indicate any of the following errors:
System Error:
Error in the control box (relay, electrodes, automation,
motherboard).
- The water pumps are switched off.
- No flush cycle is possible.
•
The Main Switch is switched off
•
Pull all the plugs out of the box
•
Unplug the system's power supply cable
•
Switch the F1 automat off and then on again
•
Close the box and reconnect it to power
•
Switch the Main Switch on again
•
If the error continues, contact Filtreco
Level Error:
The water level in the filter has become too low. More water is
being pumped out of the filter than is flowing into it.
- The water pumps are switched off.
- No flush cycle is possible.
•
Remove the cover and look for what's causing the problem.
•
Check the inlet and outlet lines.
•
If the outer end of the flush level is under water again:
- place the cover on the filter
- press "Reset Error"
- The mode will then switch to Manual
•
Press "Start" to initiate the manual flush cycle.
- The "Flush" LED turns green
- Check to make sure the spray pump and motor are working
- If the motor is not working, check whether its plug is
connected
- If the spray pump is not working, check whether its plug
is connected
- When the flush cycle is complete, the "Flush" LED
switches off again.
- Remove the cover and check whether the water level
has reached the required operating level again
- Repeat the steps above if necessary
- If this continues to happen, you must increase the inflow
capacity to the filter or reduce the pump capacity from
the filter.
Door Error:
The cover (contact) is not closed. The cover is not installed or
is not closed properly.
- The water pumps are switched off.
- No flush cycle is possible.
•
Check whether the cover is closed properly
•
Press "Reset Error" to return to the manual cycle
•
The "Door" LED switches off and the "Manual" LED
switches on
•
Press "Change Mode" to return to automatic mode.
If the error continues, check whether the magnet is still in place
under the holder for the cover. If so, then perform the following
steps:
•
Switch off the "Main Switch"
•
Disconnect the power plug from the mains
•
Open the box
•
Check whether the DR+ and DR- cables are properly
connected
Interval Error:
This occurs when 50 flush cycles have occurred in a row with
a pause of less than 3 minutes between each cycle. This may
occur when the water is heavily contaminated.
- The water pumps are switched off.
•
Set the flush electrode to the lowest level. Now, a flush cycle
will be initiated later.
•
Check the inflow lines to see whether they are clogged.
•
Check the sprayer heads and clean them if needed.
If this does not help, reduce the outgoing flow until the most
heavy contamination is eliminated.
7 Auto mode LEd:
The LED glows then the system is in automatic mode.
8 manual mode LEd:
The LED glows when the system is in manual mode.