background image

1

www.filtreco.nl

It is

clear.

www.filtreco.nl

100

300 

User manual

Drum 35 (gravity)

EN

Ord

E

N

umb

E

r

Summary of Contents for 100300

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100300 User manual Drum 35 gravity EN Order number...

Page 2: ......

Page 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Drum 35 gravity By purchasing this F...

Page 4: ......

Page 5: ...tions 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting wa...

Page 6: ...ass the drum and flow past it without being filtered This enables you to still use the biological filtration segment The basin is fitted with a removable waste drain The inclined surface accelerates t...

Page 7: ...For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications...

Page 8: ...diameter Make sure that the duct is positioned at an adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and als...

Page 9: ...g for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket...

Page 10: ...d or stop the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work...

Page 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must increase the inflow capacity to the filter or r...

Page 12: ...ge Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After yo...

Page 13: ...al between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of t...

Page 14: ...14 Drum 35 gravity 16 Technical diagram...

Page 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P...

Page 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand...

Reviews: