9.4
Mechanical installation
CAUTION!
High pressure at the drain valve!
Risk of injury to persons or damage to property
•
Depressurise prior to mounting and dismantling.
CAUTION!
High pressure at the external pressure valve!
Risk of injury to persons or damage to property
•
Depressurise prior to mounting and dismantling.
Special mounting instructions for the external
pressure and drain lines
Cleaning with compressed air:
•
Ensure sufficient pressure for cleaning
and for operating the drain valve (provide
separate compressed air connections if
necessary).
•
Make sure that the drain line is securely fastened.
•
Provide splash protection if necessary.
•
Lay the pipes without a siphon if possible, to prevent any
risk of clogging due to sedimented concentrate.
1
2
bar
kPa
psi
Fig. 5:
Mechanical installation (nodular cast iron
version)
9.5
Electro-pneumatic connections
DANGER!
Danger of electric shock!
Risk of serious or fatal injury in case of
contact with electrical components.
•
All electrical installation work must be
carried out by a suitably qualified
electrician.
9.5.1 Connection to customer's controller
Gear motor
•
Refer to the name-plate and/or the contract
documentation for details of the ratings (see also terminal
box connection diagram).
•
Install a suitable motor circuit-breaker.
•
Connect the gear motor.
Fig. 6:
Standard gear motor connections
Differential gauge / switch (optional)
•
Refer to the enclosed manufacturer’s documentation for
details of the connections.
400 V 3~ 230 V 3~
Dismantling
clearance
(
≥
380 mm)
Allow sufficient clearance
for discharging
Drain
Inlet
Outlet
105 mm