15.6 Removing the filter insert
DANGER!
The automatic filter is pressurised!
Risk of injury to persons or damage to property
•
Make sure that the pipe is depressurised prior to
opening the automatic filter.
The numbers indicated in parentheses
correspond to those used in the spare parts
drawing.
•
Carry out the preliminary maintenance steps
(section 15.2).
•
Remove the gear motor (section 15.3).
•
Remove the solenoid (1.9.13)
(section 15.5.1, steps 1-2).
1
•
Loosen and remove the hexagon screws (5) and the
washer (6) on the filter cover.
Fig. 22:
Loosening the hexagon screws on the filter
cover
2
•
Apply a large screwdriver to the notch.
•
Lever off the filter cover.
3
•
Lift up the filter insert by the eyebolts and withdraw it
vertically.
1
2
bar
kPa
psi
Fig. 23:
Withdrawing the filter insert
•
Lay the filter insert down carefully on a level surface,
taking care not to damage the segmented element and
the backflush adapter.
The filter insert can now be maintained.
•
Install in reverse order.
•
Lower the filter insert into position, making sure it is